71
Height 198mm, width 138mm, depth 40mm.
Mounting
Panel ‘instrument’ mounting (standard) hole size 102mm
diameter.
‘U’ bracket on surface mount (option).
Connection
1 metre cable with screw terminal block.
Expanded system connection with NAV6
hub
.
Environmental
Inside/outside mounting.
Waterproof to IEC945 (exposed category)
IEC 945 (EMC).
CE marked.
Power requirements
Voltage range 10.8V to 15.6V.
Consumption
(Typical)
Backlight full 310 mA (3.8 W at 12V).
Backlight off 165 mA (2.0 W at 12V).
Sleep mode 115 mA (1.4 W at 12V).
Data input
NMEA input port, meets the electrical requirements of NMEA
0183.
NMEA GPS/Instrument system interface supports NMEA 0183
V2.0 or higher.
Input/output Interface Specification
Preferred NMEA sentences: RMC, HDT, HDG, VBW, MWV,
VLW, DPT, ROT, VDR, RMB and BWC.
Minimum recommended NMEA sentences: RMC and RMB.
Data outpu
t:
RS232 serial data, supports the printing of vessel ‘Log reports‘
and NAVTEX message text to NAV6
printer
or a computer
system running compatible software.
NMEA logging Interval
off,15, 20, 30 mins, 1, 2, 3, 4, 5, 6,12 hours.
256 log entries.
NMEA Repeater Display
9 user selectable NMEA instrument and navigation screens.
Summary of Contents for Nav6plus