14
OTHER FUNCTIONS
60
■
Auto power-off
The auto power-off function conveniently turns the transceiver
power OFF after a preset time in which no operations are per-
formed. In this way, when you forget to turn the power OFF,
the transceiver automatically turns itself OFF, thereby con-
serving battery power.
The time can be set to 30 min., 1 hr., 2 hrs. or turned OFF.
The selected time is retained even when the transceiver is
turned OFF via the auto power-off function. To cancel the
function, select “oF” in step
➃
below.
➀
Push [PWR] to turn power OFF.
➁
While pushing [SET], turn power ON to enter initial set
mode.
➂
Push [SET] one or more times until “PoF” appears.
• Pushing [MONI] reverses the order of selection.
➃
Rotate the tuning dial to
select the desired auto
power-off time or turn the
timer OFF (“oF”).
• “AO” appears when an auto
power-off time is set.
➄
Push [PWR] momentarily to exit initial set mode.
■
Cooling fan
setting
The transceiver has a heatsink and cooling fan to radiate
heat. The cooling fan automatically turns ON while transmit-
ting and remains ON for 2 min. after transmitting. The cool-
ing fan can be activated continuously, if desired.
➀
Push [PWR] to turn power OFF.
➁
While pushing [SET], turn power ON to enter initial set
mode.
➂
Push [SET] one or more times until “FAn” appears.
• Pushing [MONI] reverses the order of selection.
➃
Rotate the tuning dial to set the cooling fan to automatic
(“At”) or continuous (“on”).
➄
Push [PWR] momentarily to exit initial set mode.
USING
INITIAL SET MODE
USING
INITIAL SET MODE
The display shows that the
30 min. timer is selected.
AO
The display shows that the
cooling fan is set for automatic
operation.
The display shows that the
cooling fan is set for continuous
operation.