![Icom IC-207H Instruction Manual Download Page 45](http://html.mh-extra.com/html/icom/ic-207h/ic-207h_instruction-manual_611992045.webp)
9
SCAN OPERATION
40
■
Programming scan edges
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into pairs of
scan edge channels, 1A/1b to 5A/5b, in memory channels.
➀
Push [BAND] to select a band, if necessary.
➁
Set the desired frequency in VFO mode:
➥
Push [V/MHz] to select VFO mode.
➥
Set the frequency using the tuning dial.
➥
Set other data (e.g. offset frequency, etc.) if required.
➂
Push [S.MW] momentarily.
• “
!
” and the memory channel number flashes.
[EXAMPLE]:
Programming 145.30 MHz and 145.80 MHz for the VHF scan edges 1A and 1b.
Push
then
rotate
Rotate
Push
momentarily
and hold
continue pushing
Program 1b in the same manner.
MW
S.MW
Push
MW
S.MW
MW
S.MW
H I
1
9
5
H I
1
9
5
H I
1
9
5
BAND
H I
M
1
9
5
H I
M
1
9
5
➃
Rotate the tuning dial to select a scan edge channel (1A to
5A).
➄
Push [
(S.MW)
MW] for 1 sec. to program.
• 3 beeps may sound and the frequency is programmed.
• Scan edge “x”b is automatically selected when continuing to push
[
(S.MW)
MW] after programming.
➅
To program a frequency for the other pair of scan edges,
1b to 5b, repeat steps
➂
to
➄
.
• If the same frequency is programmed into both scan edges, pro-
grammed scan will not function.