SL193-011342 ED00 10-2018
41
Step
Contents
T75
Alarm PR1
Number of interventions of the pressure gauge to view the high-pressure
switch alarm: "
Pressure switch
".
Setting this value to 000, the control is deactivated (does not display the
alarm).
Note
: In each change of function, the count of interventions of the
pressure switch is RESET.
T77
Al. TimeoutPrd
Activates (Yes) or deactivates (No) the alarm "
Timeout Prd
”.
T81
Dif. Set PP
Value of the increase applied on the reading of the absorption of the
pump in the pump tube calibration process (see Calibration Pump Tube).
T82
Time Cab. x Defrost
The cabinet has a timer cycle linked to a cooling process. When the time
programmed is reached in step Time Cab. x Defrost (T82), an automatic
defrost activates for 140
’’
and this timer goes back to zero.
T84
Minutes Test Tube
Time of the pump tubes calibration (see Calibration Pump Tubes).
T85
Set TEC Cleaning
When the Hot Cleaning function is selected, the EVRC is activated with MA
and MC until reaching the value set in this step.
If the temperature has already been reached when selecting the function,
the machine stops.
T86
Reset Hours counter
1 = reduction to zero hours MA, MP, cones and events
2 = reduction to zero cones
3 = reduction to zero events
4= reduction to zero hours MA
5= reduction to zero hours MP
Once set, activates the reduction to zero at the exit of the programming
and places on 000 again (no reduction to zero) automatically.
T87
Ohm Level On
Step for the level sensor calibration.