SL193-011342 ED00 10-2018
22
That value detected is added the value Dif. Set PP (T81) and is monitored in the board the
parameter Set. Absor. PP (T29). Whenever the MP is activated, either in PRODUCTION /
STORAGE / LOAD / CLEANING, the MP will deactivate when reaching this value.
At the end of the process, the counter of MP hours automatically reduced to zero.
Cylinder Load
By pressing the key STORAGE once, and by pressing the key MIX, the "
Cylinder load
"
function is accessed.
When the process starts, the MP activates for 30’’; then, MP continues to work until reaching it
Set. Absor. PP (T29).
Cleaning / Hot Cleaning
By pressing the key STORAGE twice, the "cleaning" function is accessed.
This function activates MA with MP for 30’’. Then, the machine automatically returns to
STOP,
to prevent an excessive wear of the cylinders.
Once in CLEANING, the display shows:
In this window, the display shows on the first line (top) the temperature value detected by the
probe of the Cylinders: TEC.
By pressing CLEANING, MA activates and only the MP remains active:
In this window, the display shows in the first line (top) TEC.
MA deactivates and only MP is left.
By pressing CLEANING again, the MA reactivates while the MP deactivates:
TEC+014
Pump ON
TEC+014
Pump ON