Maintenance
6.
To purge air from cooling system, start engine and run at an
elevated idle (1,500 rpm) for approximately 10 minutes. Do
not exceed 220°F (104°C).
7.
Verify coolant concentration and adjust coolant level to MAX
level.
8.
Install deaeration tank cap (not shown) once coolant is
stabilized at MAX level.
9.
Turn OFF engine and connect EGR valve electrical
connector.
10. Verify coolant is at correct level and concentration.
11. Clear fault code that was set when EGR valve was
disconnected (consult IC Bus
®
dealer).
12. Inspect and adjust coolant level as necessary, prior to daily
operation.
For vehicles with Cummins
®
B engines, see the following
instructions on filling the cooling system.
Typical Deaeration Tank for Cummins B Engine. (tanks
may vary)
1.
COLD MAX lines
2.
Vented fill cap
3.
COLD MIN (ADD) line
210