v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
IP address of default gateway
modified from %1 to %2 by user
%3s.
(%1 = CIM_IPProtocolEndpoint.
GatewayIPv4Address;
%2 =
CIM_StaticIPAssignmentSettingData.
DefaultGatewayAddress;
%3 = user ID)
Info
A user has modified the
default gateway IP address
of the IMM.
No action; information only.
OS Watchdog response %1 by %2.
(%1 = Enabled or Disabled; %2 =
user ID)
Info
A user has enabled or
disabled an OS Watchdog.
No action; information only.
DHCP[%1] failure, no IP address
assigned.
(%1 = IP address,
xxx
.
xxx
.
xxx
.
xxx
)
Info
A DHCP server has failed to
assign an IP address to the
IMM.
1. Make sure that the network
cable is connected.
2. Make sure that there is a
DHCP server on the network
that can assign an IP address
to the IMM.
Remote Login Successful. Login ID:
%1 from %2 at IP address %3.
(%1 = user ID; %2 =
ValueMap(CIM_ProtocolEndpoint.
ProtocolIFType; %3 = IP address,
xxx
.
xxx
.
xxx
.
xxx
)
Info
A user has successfully
logged in to the IMM.
No action; information only.
Attempting to %1 server %2 by user
%3.
(%1 = Power Up, Power Down,
Power Cycle, or Reset; %2 =
IBM_ComputerSystem.
ElementName; %3 = user ID)
Info
A user has used the IMM to
perform a power function on
the server.
No action; information only.
Security: Userid: '%1' had %2 login
failures from WEB client at IP
address %3.
(%1 = user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in the firmware);
%3 = IP address,
xxx
.
xxx
.
xxx
.
xxx
)
Error
A user has exceeded the
maximum number of
unsuccessful login attempts
from a Web browser and has
been prevented from logging
in for the lockout period.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system administrator
reset the login ID or
password.
Security: Login ID: '%1' had %2
login failures from CLI at %3.
(%1 = user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in the firmware);
%3 = IP address,
xxx
.
xxx
.
xxx
.
xxx
)
Error
A user has exceeded the
maximum number of
unsuccessful login attempts
from the command-line
interface and has been
prevented from logging in for
the lockout period.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system administrator
reset the login ID or
password.
50
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Summary of Contents for System x3200 M3
Page 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 281: ......
Page 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...