Removing the microprocessor and fan sink
To remove the microprocessor and fan sink, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 141.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Turn the server on its side so that it is lying flat, with the cover facing up.
4. Unlock and remove the side cover (see “Removing the side cover” on page
145).
5. Remove the lower bezel (see “Removing the lower bezel” on page 147).
6. Remove the hard disk drives.
7. Press and hold the drive cage release tab; then, rotate the drive cage out of
the chassis until the retaining tab on top of the cage locks into place.
8. Disconnect any cables that impede access to the fan sink and microprocessor.
Attention:
The fan-sink retention lever is spring-loaded when the fan sink is
in place. Releasing the lever too quickly or allowing it to spring upward can
damage the fan sink and surrounding components.
9. Remove the fan sink from the microprocessor:
a. Disconnect the fan-sink cable from the system board.
b. Release the fan-sink retention lever by pressing down on the end, moving
it to the side and slowly releasing it to the open (up) position.
Important:
Be careful when you handle the microprocessor and fan sink.
If the microprocessor and fan sink will be reused, do not contaminate the
thermal material between them.
Orientation indicators
Fan-sink retention lever
Chapter 5. Removing and replacing server components
209
Summary of Contents for System x3200 M3
Page 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 281: ......
Page 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...