v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Flash of %1 from %2 failed for user
%3.
(%1 = CIM_ManagedElement.
ElementName;
%2 = Web or LegacyCLI;
%3 = user ID)
Info
An attempt to update a
firmware component from the
interface and IP address has
failed.
Try to update the firmware again.
The Chassis Event Log (CEL) on
system %1 is 75% full.
(%1 = CIM_ComputerSystem.
ElementName)
Info
The IMM event log is 75%
full. When the log is full,
older log entries are replaced
by newer ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
The Chassis Event Log (CEL) on
system %1 is 100% full.
(%1 = CIM_ComputerSystem.
ElementName)
Info
The IMM event log is full.
When the log is full, older log
entries are replaced by
newer ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
%1 Platform Watchdog Timer
expired for %2.
(%1 = OS Watchdog or Loader
Watchdog; %2 = OS Watchdog or
Loader Watchdog)
Error
A Platform Watchdog Timer
Expired event has occurred.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface is
enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for the
operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
IMM Test Alert Generated by %1.
(%1 = user ID)
Info
A user has generated a test
alert from the IMM.
No action; information only.
Security: Userid: '%1' had %2 login
failures from an SSH client at IP
address %3.
(%1 = user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in the firmware);
%3 = IP address,
xxx
.
xxx
.
xxx
.
xxx
)
Error
A user has exceeded the
maximum number of
unsuccessful login attempts
from SSH and has been
prevented from logging in for
the lockout period.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system administrator
reset the login ID or
password.
54
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Summary of Contents for System x3200 M3
Page 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 281: ......
Page 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...