Removing the SAS/SATA hard disk drive backplane
This procedure applies only to hot-swap server models with a SAS/SATA hard disk
drive backplane installed on the back of the hard disk drive cage.
Note:
A 3.5-inch hard disk drive model is used as an example. It is also applicable
for 2.5-inch hard disk drive model.
To remove the SAS/SATA hard disk drive backplane, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 141.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see “Removing the side cover” on page
145).
4. Remove the lower bezel (see “Removing the lower bezel” on page 147).
5. Remove the hot-swap SAS/SATA hard disk drives installed in the hard disk
drive cage (see “Removing a hot-swap hard disk drive” on page 160).
6. Remove the hard disk drive fan assembly from the hard disk drive cage (see
“Removing the hard disk drive fan assembly” on page 189).
7. Disconnect the power and signal cables from the hard disk drive backplane.
8. Press and hold the drive cage release tab; then, rotate the drive cage out of
the chassis until the retaining tab on top of the cage locks into place.
9. Remove the two screws that secure the SAS/SATA hard disk drive backplane
to the drive cage.
Retaining tab
Drive cage
release tab
Retaining
latch
Locating pins
10. Tilt the top of the hard disk drive backplane away from the drive cage until it is
clear of the locating pins.
11. Lift the SAS/SATA hard disk drive backplane out of the lower lip on the drive
cage and set it aside.
Chapter 5. Removing and replacing server components
195
Summary of Contents for System x3200 M3
Page 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Page 281: ......
Page 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...