Table C-1. TapeAlert Flags Supported by the Ultrium Tape Drive (continued)
Flag
Number
Flag
Description
Action Required
18
Tape directory corrupted
in the cartridge memory
Set when the drive detects that the
tape directory in the cartridge
memory has been corrupted.
Re-read all data from the tape to
rebuild the tape directory.
19
Nearing media life
Set when the tape cartridge is nearing
its specified end of life. The flag is
cleared when the cartridge is removed
from the drive.
1.
Copy the data to another tape
cartridge.
2.
Replace the tape cartridge.
20
Clean now
Set when the tape drive detects that it
needs cleaning.
Clean the tape drive.
21
Clean periodic
Set when the drive detects that it
needs routine cleaning.
Clean the tape drive as soon as
possible. The drive can continue to
operate, but you should clean the
drive soon.
22
Expired clean
Set when the tape drive detects a
cleaning cartridge that has expired.
Replace the cleaning cartridge.
23
Invalid cleaning tape
Set when the drive expects a cleaning
cartridge and the loaded cartridge is
not a cleaning cartridge.
Use a valid cleaning cartridge.
30
Hardware A
Set when a hardware failure occurs
that requires that you reset the tape
drive to recover.
Go to“Contacting IBM Technical
Support” on page 9-4.
31
Hardware B
Set when the tape drive fails its
internal Power-On Self Tests.
Note the error code on the
single-character display, then go
to“Contacting IBM Technical
Support” on page 9-4.
32
Interface
Set when the tape drive detects a
problem with the host interface.
Go to“Contacting IBM Technical
Support” on page 9-4.
33
Eject media
Set when a failure occurs that requires
you to unload the cartridge from the
drive.
Unload the tape cartridge, then
reinsert it and restart the operation.
34
Download fail
Set when an FMR image is
unsuccessfully downloaded to the
tape drive through the host interface.
Ensure that it is the correct FMR
image. Download the FMR image
again.
37
Drive voltage
Set when the drive detects that the
externally supplied voltages are either
approaching the specified voltage
limits or are outside the voltage
limits.
Go to“Contacting IBM Technical
Support” on page 9-4.
38
Predictive failure of
drive hardware
Set when a hardware failure of the
tape drive is predicted.
Go to“Contacting IBM Technical
Support” on page 9-4.
39
Diagnostics required
Set when the drive detects a failure
that requires diagnostics for isolation.
Go to“Contacting IBM Technical
Support” on page 9-4.
51
Tape directory invalid at
unload
Set when the tape directory on the
tape cartridge that was previously
unloaded is corrupted. The file-search
performance is degraded.
Use your backup software to
rebuild the tape directory by
reading all the data.
52
Tape system area write
failure
Set when the tape cartridge that was
previously unloaded could not write
its system area successfully.
Copy the data to another tape
cartridge, then discard the old
cartridge.
C-4
TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide
Summary of Contents for System Storage TS3100
Page 2: ......
Page 12: ...x TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 16: ...xiv TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 18: ...xvi TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 30: ...xxviii TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 110: ...4 44 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 190: ...5 80 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 240: ...8 14 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 246: ...9 6 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 318: ...B 8 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 348: ...F 2 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 352: ...H 2 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 372: ...X 4 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Page 373: ......
Page 374: ...Part Number 35P2859 Printed in USA GA32 0545 12 1P P N 35P2859...