1.
To help you work safely with Storwize V7000 Unified file modules, read the
safety information in “Safety” on page xi, “Safety statements” on page xiii, and
“Installation guidelines” on page 54.
2.
Install the adapter in the expansion slot.
3.
If the adapter is a full-length adapter for the upper expansion slot (1 or 3) in
the riser card, remove the full-length-adapter bracket
1
from beneath the top
of the riser-card assembly
3
and insert it in the end of the upper expansion
slot
2
of the riser-card assembly.
a.
Align the adapter with the PCI connector on the riser-card, and the guide
on the external end of the riser-card assembly.
b.
Press the adapter firmly into the PCI connector on the riser card.
4.
Reconnect any internal cables that you disconnected.
Attention:
v
When you route cables, do not block any connectors or the ventilated space
around any of the fans.
v
Make sure that cables are not routed on top of components under the PCI
riser-card assemblies.
v
Make sure that cables are not pinched by server components.
5.
Align the PCI riser-card assembly with the selected PCI connector on the
system board.
v
PCI-riser connector 1:
Carefully fit the two alignment slots on the side of the
assembly onto the two alignment brackets on the side of the chassis; align
the rear of the assembly with the guides on the rear of the server.
v
PCI-riser connector 2:
Carefully align the bottom edge (the contact edge) of
the riser-card assembly with the riser-card connector on the system board;
align the rear of the assembly with the guides on the rear of the server.
6.
Perform any configuration tasks that are required for the adapter.
7.
Install the cover, as described in “Installing the cover” on page 84.
8.
Slide the file module into the rack.
9.
Reconnect the external cables; then, reconnect the power cords and turn on the
peripheral devices and the file module.
Note:
You must wait approximately 2.5 minutes after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
Removing a Fibre Channel PCI adapter
These removal instructions show the slot location for the Fibre Channel PCI
adapter.
104
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...