Problem: Management GUI or service assistant does not
display correctly
This topic provides assistance if the management GUI or the service assistant does
not display correctly.
You must use a supported web browser. Verify that you are using a supported web
browser from the following website:
www.ibm.com/storage/support/storwize/v7000/unified
Switch to using a supported web browser. If the problem continues, contact IBM
Support.
Problem: Node canister location error
The node error that is listed on the service assistant home page or in the event log
can indicate a location error.
To find out how to resolve the node error, go to “Procedure: Fixing node errors”
on page 204.
Be aware of the following items:
v
Each control enclosure must have two node canisters installed.
v
Node canisters and expansion canisters are not interchangeable. A node canister
cannot operate in an expansion enclosure. An expansion canister cannot operate
in a control enclosure.
v
After the node has been used in a clustered system, the node canister has saved
information that can identify whether the canister has been moved to a different
enclosure or a different slot in the same enclosure from where it was previously
used. Moving a node canister might compromise its access to storage or access
to volumes by a host application. Do not move the canister from its original
location unless directed to do so by a service action.
Problem: SAS cabling not valid
This topic provides information to be aware of if you receive errors that indicate
the SAS cabling is not valid.
Check the following items:
v
No more than five expansion enclosures can be chained to port 1 (below the
control enclosure). The connecting sequence from port 1 of the node canister is
called chain 1.
v
No more than four expansion enclosures can be chained to port 2 (above the
control enclosure). The connecting sequence from port 2 of the node canister is
called chain 2.
v
Do not connect a SAS cable between a port on an upper canister and a port on a
lower canister.
v
In any enclosure, the same ports must be used on both canisters.
v
No SAS cable can be connected between ports in the same enclosure.
v
For any enclosure, the cables that are connected to SAS port 1 on each canister
must attach to the same enclosure. Similarly, for any enclosure, the cables that
are connected to SAS port 2 on each canister must attach to the same enclosure.
Cable attachments for SAS port 1 and cable attachments for SAS port 2 do not
go to the same enclosure.
194
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...