Table 46. Upgrade error codes and recommended actions (continued)
Error
Code
Explanation
Action
01B9
Failed to check the Storwize V7000
version.
This could be caused by a number of
issues. Check
Monitoring > Events
under
both the
block
tab and the
file
tab on the
management GUI for an event that could
have caused this error and follow the
recommended action. If there is no
obvious event that could have caused
this error, refer to “File module to control
enclosure” on page 27.
01BA
Unable to verify the correct
software version.
Contact your next level of support.
01BC
Check the health of DDN storage
systems.
Contact your next level of support.
01BD
Unable to update software
repository.
Contact your next level of support.
01BE
Unable to distribute upgrade
callbacks.
Contact your next level of support.
01C0
Asynchronous replication is
running. Stop asynchronous
replication and continue with the
upgrade.
Stop asynchronous replication by typing
stoprepl gpfs0 --kill
.
01C1
Asynchronous replication failed to
stop. Stop asynchronous replication
and continue with the upgrade.
Stop asynchronous replication by typing
stoprepl gpfs0 --kill
.
01C2
Failed while checking for current
running asynchronous jobs.
Type
lsrepl;echo $?
. If the return code
is 0, start the upgrade again. If the return
code is any other number, contact your
next level of support.
01C3
Could not stop CTDB.
Contact your next level of support.
01C5
Could not reinstall Lib_Utils.
Contact your next level of support.
01C6
Failed while running
sonas_update_yum.
Contact your next level of support.
01C7
Unable to get list of system nodes.
Contact your next level of support.
01C8
Failed while running
cnrsscconfig
. Contact your next level of support.
01C9
Unable to install CIM
configuration.
Contact your next level of support.
01CA
Unable to get name of system.
Contact your next level of support.
01CB
Unable to install GPFS packages.
Contact your next level of support.
01CC
Could not install platform. Upgrade
on target system.
Contact your next level of support.
01CD
Unable to mount GPFS file systems. See “Checking the GPFS file system
mount on each file module” on page 162.
01CF
Unable to configure node.
Contact your next level of support.
01D0
Unable to disable call home.
Contact your next level of support.
01D1
Unable to enable call home.
Contact your next level of support.
01D2
Failed to stop GPFS.
Contact your next level of support.
270
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...