Table 46. Upgrade error codes and recommended actions (continued)
Error
Code
Explanation
Action
01D3
Could not determine if backups are
running.
Type
lsjobstatus -j backup;echo $?
. If
the return code is 0, start the upgrade
again. If the return code is any other
number, contact your next level of
support.
01D5
Storwize V7000
stalled_non_redundant.
Contact your next level of support.
01D6
Storwize V7000 system stalled.
Contact your next level of support.
01D8
CTDB system is unhealthy.
See “Checking CTDB health” on page
160.
01DA
GPFS system is unhealthy.
See “Checking the GPFS file system
mount on each file module” on page 162.
01DB
Failed to stop performance center.
Contact your next level of support.
01DC
Failed to configure performance
center.
Contact your next level of support.
01DD
Failed to start performance center.
Contact your next level of support.
01DE
Unable to communicate with
passive management node.
Verify that the other management node is
up and that TCP/IP communication is
working. Then start the upgrade again.
01DF
Upgrade must be resumed from the
other management node.
Start the upgrade again from the other
management node. This might require
that a failover be issued first.
01E0
HSM upgrade failed.
Contact your next level of support.
Chapter 7. Recovery procedures
271
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...