![IBM Storwize V7000 Problem Determination Manual Download Page 150](http://html.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_problem-determination-manual_4062780150.webp)
e.
If you are instructed to return the ServeRAID SAS controller battery, follow
all packaging instructions, and use any packaging materials for shipping
that are supplied to you.
Installing the serveRAID SAS controller battery on the remote
battery tray
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
Note:
Before running a procedure, refer to “Removing a file module to perform a
maintenance action” on page 51.
To install the serveRAID SAS controller battery on the remote battery tray,
complete the following procedure.
1.
Place the replacement battery on the battery carrier from which the former
battery had been removed, and connect the battery carrier cable to the
replacement battery.
2.
Connect the remote battery cable to the interposer card.
Attention:
To avoid damage to the hardware, make sure that you align the
black dot on the cable connector with the black dot on the connector on the
interposer card. Do not force the remote battery cable into the connector. See
Figure 35 on page 127
Battery
carrier
Battery
Battery
cable
Battery
connector
Remote battery
cable connector
sonas219
Figure 34. Removing the battery from the battery carrier
126
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...