Table 23. SMART ASC/ASCQ error codes and messages
ASC
ASCQ
Description
00
00
NO ADDITIONAL SENSE INFORMATION
00
06
I/O PROCESS TERMINATED
00
16
OPERATION IN PROGRESS
00
17
CLEANING REQUESTED
00
1D
ATA PASS THROUGH INFORMATION AVAILABLE
00
1E
CONFLICTING SA CREATION REQUEST
00
1F
LOGICAL UNIT TRANSITIONING TO ANOTHER POWER
CONDITION
01
00
NO INDEX/SECTOR SIGNAL
02
00
NO SEEK COMPLETE
03
00
PERIPHERAL DEVICE WRITE FAULT
04
00
LOGICAL UNIT NOT READY
04
01
LOGICAL UNIT IS IN PROCESS OF BECOMING READY
04
02
LOGICAL UNIT NOT READY, INITIALIZING COMMAND REQUIRED
04
03
LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
04
04
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
04
05
LOGICAL UNIT NOT READY, REBUILD IN PROGRESS
04
06
LOGICAL UNIT NOT READY, RECALCULATION IN PROGRESS
04
07
LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
04
09
LOGICAL UNIT NOT READY, SELF-TEST IN PROGRESS
04
0A
LOGICAL UNIT NOT ACCESSIBLE, ASYMMETRIC ACCESS STATE
TRANSITION
04
0B
LOGICAL UNIT NOT ACCESSIBLE, TARGET PORT IN STANDBY
STATE
04
0C
LOGICAL UNIT NOT ACCESSIBLE, TARGET PORT IN
UNAVAILABLE STATE
04
10
LOGICAL UNIT NOT READY, AUXILIARY MEMORY NOT
ACCESSIBLE
04
11
LOGICAL UNIT NOT READY, NOTIFY (ENABLE SPINUP) REQUIRED
04
13
LOGICAL UNIT NOT READY, SA CREATION IN PROGRESS
04
14
LOGICAL UNIT NOT READY, SPACE ALLOCATION IN PROGRESS
04
1A
LOGICAL UNIT NOT READY, START STOP UNIT COMMAND IN
PROGRESS
05
00
LOGICAL UNIT DOES NOT RESPOND TO SELECTION
06
00
NO REFERENCE POSITION FOUND
07
00
MULTIPLE PERIPHERAL DEVICES SELECTED
08
00
LOGICAL UNIT COMMUNICATION FAILURE
08
01
LOGICAL UNIT COMMUNICATION TIME-OUT
08
02
LOGICAL UNIT COMMUNICATION PARITY ERROR
Chapter 4. File module
65
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...