2.
If you are planning to view the error LEDs that are on the system board and
components, leave the file module connected to power and go directly to step
4.
3.
If you are planning to install or remove a microprocessor, memory module, PCI
adapter, battery, or other non-hot-swap optional device, turn off the file module
and all attached devices and disconnect all external cables and power cords.
4.
Press down on the left and right side latches and pull the file module out of
the rack enclosure until both slide rails lock.
Note:
You can reach the cables on the back of the file module when the file
module is in the locked position.
5.
Push the cover-release latch back
1
, then lift it up
2
.
6.
Slide the cover back
3
, then lift the cover off the file module and set it aside.
Attention:
For proper cooling and airflow, replace the cover before turning on
the file module. Operating the file module for extended periods of time (over
30 minutes) with the cover removed might damage file modulefile module
components.
7.
If you are instructed to return the cover, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Installing the cover
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
Note:
Before running a procedure, refer to “Removing a file module to perform a
maintenance action” on page 51.
To install the cover, complete the following steps.
1.
To help you work safely with Storwize V7000 Unified file modules, read the
safety information in “Safety” on page xi, “Safety statements” on page xiii, and
“Installation guidelines” on page 54.
2.
Make sure that all internal cables are correctly routed.
3.
Place the cover-release latch in the open (up) position.
84
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...