3
Allow a 2-minute warmup. The meter turns off if you do not press a button
within 10 minutes.
4
If the meter does not display Optical Power Meter, repeatedly press the
lambda pushbutton until 1300 nm appears.
Note: To ensure that the pushbutton produces the desired results, do not
hold down the pushbutton for more than half a second.
5
Press Zero. The following two displays appear:
¹
A value between 0.30 and 0.70 nanowatts (nW)
¹
After a short time 0 blinks, indicating that the meter is correctly zeroed.
If the meter is not correctly zeroed, a Hi or Lo is displayed after you press
Zero. Press Zero again, and using a jeweler’s screwdriver, adjust the trim
pot that is beside the biconic receptacle at the top of the meter until a
value between 0.30 and 0.70 nW is displayed. Set the value to 0.50, if
possible.
6
Press Zero again to zero the meter.
The meter must also display dBm. If nW is displayed, press dBm/Watt. The
optical power meter is now set.
7
After you set the meter, connect the black biconic connector of the test cable
to the biconic receptacle on top of the power meter.
8
Enter 1 to start the test as indicated in the following example.
@
Screen 1 of 1
Setup For Optical Test
LIC 287 - ESCON Channel Adapter, Slot 4, Net # 0
Operational Status
Diagnostic Status
Fault Status
Network Connection
DISABLED
TESTING
UNKNOWN
UNKNOWN
Do not remove this device while testing.
Install the duplex-to-biconic test cable connector to the ESCON
channel adapter located in slot 4.
Set the optical power meter to the following options:
* -- Power turned on
* -- Set for 1300 nanometers (nm)
* -- Zeroed
* -- The decibel scale displayed (dBm)
Confirm the meter is set.
< 1. Start > the adapter transmitter.
Select (1 or
B=Back R=Refresh H=Help ):1
The green port LED on the 2216 ESCON Adapter will start blinking once the
adapter has started transmitting the idle sequences. At this point, record the
signal level displayed on the power meter. A correctly functioning 2216
ESCON adapter should have a power level of -21.0 dBm or more (for
example, -18.0 dBm).
9
Replace the ESCON Channel Adapter if its power level is too low.
Chapter 5. Using Operational Diagnostics
5-17
Summary of Contents for Nways 2216
Page 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Page 2: ......
Page 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Page 8: ...vi 2216 Maintenance Manual ...
Page 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Page 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Page 60: ...3 6 2216 Maintenance Manual ...
Page 84: ...4 24 2216 Maintenance Manual ...
Page 104: ...A 2 2216 Maintenance Manual ...
Page 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Page 110: ...B 6 2216 Maintenance Manual ...
Page 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Page 138: ...F 12 2216 Maintenance Manual ...
Page 164: ......
Page 167: ......