Preparing the expansion unit
This section explains how to prepare the expansion unit for
installation by removing the CRUs (customer replaceable
units) and by setting the interface options.
Removing CRUs
It is easier to lift the expansion unit and install it in a rack
or tower enclosure if you remove all CRUs (drives, fans,
and power supplies) first. A fully loaded expansion unit
with 10 disk drives, two fan units, and the second power
supply installed weighs 36.1 kg (79.5 lbs). The standard
unit shipped with one power supply and two fan units
weighs 22.5 kg (49.5 lbs). If you remove all the CRUs,
you can reduce the overall weight.
Attention:
If you have data stored on the drives, label the drives
before you remove them. Then when you replace the
drives, install them in the exact drive bays from which you
removed them.
Attention:
The expansion unit is shipped with the decorative bezel
attached to the front of the unit with two white screws and
nuts. This bezel protects the light pipes located above the
drive trays. Leave the decorative bezel in place until you
are instructed to remove it during the installation process.
Netfinity EXP200 Type 3530
47
Summary of Contents for EXP15
Page 2: ......
Page 8: ...vi IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 30: ...Parts Listing 1 2 3 4 5 6 7 8 22 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 65: ...Parts Listing 1 2 3 4 5 6 7 Netfinity EXP200 Type 3530 57...
Page 68: ...60 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 116: ...Parts Listing 1 2 3 4 5 6 7 108 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 124: ...116 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 125: ...Notice n 1 Related Service Information 117...
Page 132: ...124 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 145: ......
Page 146: ...IBM Part Number 09N1393 Printed in U S A S1 L 9839 1...