![background image](http://html1.mh-extra.com/html/ibm/exp15/exp15_hardware-maintenance-manual_3992345112.webp)
Fan controls and indicators:
The fans in your
Netfinity FAStT EXP500 are hot-swappable and redundant.
This means that your Netfinity FAStT EXP500 will continue
to operate if a fan fails. It also means that you can
remove and replace the fan while the Netfinity FAStT
EXP500 is on and accessing drives.
Attention
The fans in your expansion unit draw in fresh air and
force out hot air. These fans are hot-swappable and
redundant; however, when one fan fails, the fan unit
must be replaced within 48 hours in order to maintain
redundancy and optimum cooling. When you replace
the failed unit, be sure to install the second fan within
10 minutes to prevent any overheating due to the lack
of the additional fan unit.
Fan
CRUs:
The two fan CRUs are located here. These
fans are hot-swappable and redundant.
Fault
LEDs:
These amber LEDs light when a fan failure
occurs.
Latches
and
handles:
Use the latches and handles to remove or
install the fan CRUs.
104
IBM Netfinity EXP15, EXP200, EXP500 HMM
Summary of Contents for EXP15
Page 2: ......
Page 8: ...vi IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 30: ...Parts Listing 1 2 3 4 5 6 7 8 22 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 65: ...Parts Listing 1 2 3 4 5 6 7 Netfinity EXP200 Type 3530 57...
Page 68: ...60 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 116: ...Parts Listing 1 2 3 4 5 6 7 108 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 124: ...116 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 125: ...Notice n 1 Related Service Information 117...
Page 132: ...124 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 145: ......
Page 146: ...IBM Part Number 09N1393 Printed in U S A S1 L 9839 1...