b. If the amber Fault LED is completely on and not
flashing, remove the drive from the unit and wait
10 seconds; then, reinstall the drive.
8. Configure the drive using the appropriate software.
Replacing hot-swap drives:
Drive problems include
any malfunctions that delay, interrupt, or prevent
successful I/O activity between the hosts and the hard disk
drives in the expansion unit. This includes transmission
problems between the host controllers, the ESM boards,
and the drives. This section explains how to replace a
failed drive.
Attention
Failure to replace the drives in their correct bays might
result in loss of data. If you are replacing a drive that
is part of a RAID level 1 or RAID level 5 logical drive,
ensure that you install the replacement drive in the
correct bay.
Check the hardware and software documentation provided
with your system to see if there are restrictions regarding
hard disk drive configurations. Some system Fibre
Channel (FC) configurations might not allow mixing
different drive capacities or types within an array.
1. Determine the location of the drive that you want to
remove.
Attention
Never hot swap a drive CRU when its green
Activity LED is flashing. Hot swap a drive CRU
only when its amber Fault LED is completely on
and not flashing or when the drive is inactive with
the green Activity LED completely on and not
flashing.
2. Remove the drive CRU.
a. Press on the inside of the bottom of the tray
handle to release the blue latch
1
.
b. Pull the handle
2
on the tray
3
out into the
open position.
c. Lift the drive CRU partially out of the bay.
d. To avoid possible damage to the drive
4
, wait
at least 20 seconds before fully removing the
drive CRU from the expansion unit to allow for
the drive to spin down.
88
IBM Netfinity EXP15, EXP200, EXP500 HMM
Summary of Contents for EXP15
Page 2: ......
Page 8: ...vi IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 30: ...Parts Listing 1 2 3 4 5 6 7 8 22 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 65: ...Parts Listing 1 2 3 4 5 6 7 Netfinity EXP200 Type 3530 57...
Page 68: ...60 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 116: ...Parts Listing 1 2 3 4 5 6 7 108 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 124: ...116 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 125: ...Notice n 1 Related Service Information 117...
Page 132: ...124 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 145: ......
Page 146: ...IBM Part Number 09N1393 Printed in U S A S1 L 9839 1...