e. Verify that there is proper identification (such as
a label) on the drive CRU, then slide it
completely out of the expansion unit.
f. If you are replacing a slim-line drive, ensure that
the filler piece remains in place for use with the
new drive.
3. Install the new drive CRU.
a. Gently push the drive CRU into the empty bay
until the tray handle
2
touches the expansion
unit bezel.
b. Push the tray handle
2
down into the closed
(latched) position.
4. Check the drive LEDs.
a. When a drive is ready for use, the green Activity
LED is on and the amber Fault LED is off.
b. If the amber Fault LED is completely on and not
flashing, remove the drive from the unit and wait
10 seconds; then, reinstall the drive.
5. Return to normal operation.
Working with hot-swap power supplies:
The
power supplies are customer replaceable units (CRUs) and
do not require preventive maintenance.
The power supplies must always be in their proper
places to maintain proper expansion-unit cooling.
Use only the supported power supplies for your
specific expansion unit.
Removing a hot-swap power supply:
Netfinity FAStT EXP500 - Type 3560
89
Summary of Contents for EXP15
Page 2: ......
Page 8: ...vi IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 30: ...Parts Listing 1 2 3 4 5 6 7 8 22 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 65: ...Parts Listing 1 2 3 4 5 6 7 Netfinity EXP200 Type 3530 57...
Page 68: ...60 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 116: ...Parts Listing 1 2 3 4 5 6 7 108 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 124: ...116 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 125: ...Notice n 1 Related Service Information 117...
Page 132: ...124 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Page 145: ......
Page 146: ...IBM Part Number 09N1393 Printed in U S A S1 L 9839 1...