22003002
Gigabit
Ethernet
adapter
failure.
If
the
location
code
identifies
a
slot:
1.
Reseat
the
adapter
and
restart
the
blade
server.
2.
Replace
the
adapter.
3.
Check
the
http://www.ibm.com/pc/support/
Web
site
for
system
firmware
updates.
Apply
the
latest
update,
if
one
is
available.
4.
If
an
update
is
not
available,
contact
a
system
administrator
for
assistance.
If
the
location
code
identifies
the
system,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
22003003
Gigabit
Ethernet
adapter
failure.
If
there
is
no
adapter
in
the
PCI
slot
in
the
blade
server,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
If
there
is
an
adapter
in
the
PCI
slot
in
the
blade
server,
perform
the
following
steps:
1.
Turn
off
the
blade
server.
2.
Remove
the
adapter;
then,
turn
on
the
blade
server.
3.
If
the
problem
no
longer
exists,
replace
the
adapter
that
you
removed.
If
the
problem
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A00001
Level
2
(L2)
cache
controller
failure.
Replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A10001
L2
cache
static
random-access
memory
(SRAM)
failure.
Replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A80xxx
Nonvolatile
random-access
memory
(NVRAM)
problems.
NVRAM
errors
are
caused
by
low-battery
voltage
or
power
outages
that
occur
during
normal
system
usage.
Except
for
firmware
error
code
2580000,
these
error
codes
are
warnings
that
the
NVRAM
data
content
had
to
be
reestablished,
and
do
not
require
any
component
replacement,
unless
the
problem
remains.
When
one
of
these
error
occurs,
any
system
customization
(for
example,
the
startup
device
sequence)
has
been
lost.
If
the
problem
remains,
replace
the
battery
in
the
blade
server.
For
additional
information,
see
Note:
After
you
replace
the
battery,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
still
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
Chapter
10.
Solving
problems
81
Summary of Contents for eServer BladeCenter JS20 Type 8842
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ERserver...
Page 8: ...vi BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 28: ...12 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 72: ...56 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 114: ...98 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 136: ...120 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 149: ......
Page 150: ...Part Number 25K8416 Printed in USA 1P P N 25K8416...