Checkpoint
code
Description
Suggested
action
E1FB
Reserved
Have
the
blade
server
serviced.
E1FC
Build
the
boot
list
for
serial
storage
architecture
(SSA)
adapters.
The
location
code
of
the
SSA
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FD
E1FD
and
another
progress
code
(Exxx)
will
alternate
in
the
operator
panel.
The
other
code
indicates
where
the
error
occurred.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FE
Build
the
boot
list
for
Fibre
Channel
adapters.
The
world-wide
port
number
(WWPN)
of
the
SAN
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FF
Building
the
boot
list
for
Fibre
Channel
adapters.
The
WWPN
of
the
SAN
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E199
Restarting
(rebooting)
the
partition
to
activate
the
changes
that
are
specified
in
the
boot-image’s
executable
and
linkable
format
(ELF)
header.
1.
Check
the
http://www.ibm.com/pc/support/
Web
site
for
a
later
firmware
version
that
might
address
the
problem.
For
additional
information,
see
2.
If
a
later
firmware
version
is
not
available,
or
if
the
problem
remains
after
you
update
the
firmware
code,
go
to
the
“Boot
problem
resolution”
section
in
the
BladeCenter
JS20
Type
8842
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
.
Follow
the
instructions
in
that
section.
E200
I
2
C
bus
controller
initialization.
1.
Perform
the
system
checkout
procedure.
See
2.
If
the
problem
remains,
force
the
system
to
start
from
the
PERM
flash
image
to
reflash
the
TEMP
image
for
recovery.
See
3.
If
the
problem
remains,
replace
the
blade
server.
Contact
a
service
support
representative
for
assistance.
E201
The
flash
random-access
memory
(RAM)
cyclic
redundancy
check
(CRC)
checksum
is
valid.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E202
Programmable
interrupt
controller
(MPIC)
initialization.
1.
Perform
the
system
checkout
procedure.
See
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
Chapter
10.
Solving
problems
69
Summary of Contents for eServer BladeCenter JS20 Type 8842
Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ERserver...
Page 8: ...vi BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 28: ...12 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 72: ...56 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 114: ...98 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 136: ...120 BladeCenter JS20 Type 8842 Installation and User s Guide...
Page 149: ......
Page 150: ...Part Number 25K8416 Printed in USA 1P P N 25K8416...