background image

Checkpoint

 

codes

 

The

 

POST

 

firmware

 

checkpoints

 

(progress

 

codes)

 

indicate

 

the

 

detection

 

of

 

a

 

problem

 

if

 

the

 

server

 

stops

 

on

 

a

 

checkpoint

 

during

 

the

 

startup

 

process.

 

v

   

A

 

four-digit

 

code

 

indicates

 

successful

 

completion

 

of

 

POST

 

when

 

the

 

server

 

does

 

not

 

stop

 

on

 

that

 

checkpoint.

 

v

   

A

 

result

 

other

 

than

 

a

 

four-digit

 

code

 

indicates

 

that

 

POST

 

might

 

have

 

detected

 

a

 

problem.

 

Error

 

messages

 

also

 

appear

 

during

 

startup

 

if

 

POST

 

detects

 

a

 

hardware-configuration

 

problem.

 

The

 

last

 

POST

 

firmware

 

checkpoint

 

code

 

posted

 

is

 

the

 

most

 

likely

 

failure.

 

Checkpoints

 

display

 

in

 

the

 

system

 

console

 

from

 

the

 

time

 

that

 

ac

 

power

 

is

 

connected

 

to

 

the

 

system

 

until

 

the

 

operating-system

 

login

 

prompt

 

is

 

displayed

 

after

 

a

 

successful

 

operating-system

 

startup.

 

These

 

checkpoints

 

have

 

the

 

following

 

forms:

 

Dxxx,

 

Exxx

 

Dxxx

 

and

 

Exxx

 

checkpoints

 

indicate

 

that

 

a

 

system

 

processor

 

is

 

in

 

control

 

and

 

is

 

initializing

 

the

 

system

 

resources.

 

Control

 

passes

 

to

 

the

 

operating

 

system

 

when

 

E105

 

displays

 

on

 

the

 

operator

 

panel

 

display.

 

Location

 

code

 

information

 

might

 

also

 

display

 

on

 

the

 

operator

 

panel

 

during

 

this

 

time.

  

These

 

codes

 

range

 

from

 

Dxxx

 

to

 

EFFF.

 

Error

 

codes

 

If

 

a

 

fault

 

is

 

detected,

 

an

 

8-digit

 

error

 

code

 

is

 

displayed

 

in

 

the

 

BladeCenter

 

management-module

 

event

 

log.

 

A

 

location

 

code

 

might

 

be

 

displayed

 

at

 

the

 

same

 

time

 

on

 

the

 

second

 

line.

 

The

 

management-module

 

log,

 

which

 

can

 

be

 

accessed

 

through

 

the

 

BladeCenter

 

unit,

 

contains

 

the

 

most

 

recent

 

error

 

codes

 

and

 

messages

 

that

 

the

 

system

 

generated

 

during

 

POST.

  

Checkpoint

 

code

 

Description

 

Suggested

 

action

 

D001

 

Peripheral

 

component

 

interconnect

 

(PCI)

 

probe

 

process

 

complete;

 

create

 

PCI

 

interrupt

 

routing

 

properties.

 

1.

   

Perform

 

the

 

system

 

checkout

 

procedure.

 

See

 

“System

 

checkout”

 

on

 

page

 

58.

 

2.

   

This

 

error

 

indicates

 

that

 

you

 

might

 

have

 

a

 

problem

 

with

 

the

 

system

 

board.

 

Contact

 

a

 

service

 

support

 

representative

 

for

 

more

 

information.

 

D002

 

PCI

 

adapter

 

nonvolatile

 

random-access

 

memory

 

(NVRAM)

 

hint

 

created;

 

system

 

is

 

restarting.

 

1.

   

Perform

 

the

 

system

 

checkout

 

procedure.

 

See

 

“System

 

checkout”

 

on

 

page

 

58.

 

2.

   

This

 

error

 

indicates

 

that

 

you

 

might

 

have

 

a

 

problem

 

with

 

the

 

system

 

board.

 

Contact

 

a

 

service

 

support

 

representative

 

for

 

more

 

information.

 

D003

 

PCI

 

probing

 

is

 

complete.

 

1.

   

Perform

 

the

 

system

 

checkout

 

procedure.

 

See

 

“System

 

checkout”

 

on

 

page

 

58.

 

2.

   

This

 

error

 

indicates

 

that

 

you

 

might

 

have

 

a

 

problem

 

with

 

the

 

system

 

board.

 

Contact

 

a

 

service

 

support

 

representative

 

for

 

more

 

information.

 

D004

 

Start

 

the

 

console

 

installation;

 

loading

 

the

 

graphical

 

interface

 

package.

 

1.

   

Perform

 

the

 

system

 

checkout

 

procedure.

 

See

 

“System

 

checkout”

 

on

 

page

 

58.

 

2.

   

This

 

error

 

indicates

 

that

 

you

 

might

 

have

 

a

 

problem

 

with

 

the

 

system

 

board.

 

Contact

 

a

 

service

 

support

 

representative

 

for

 

more

 

information.

   

Chapter

 

10.

 

Solving

 

problems

 

59

Summary of Contents for eServer BladeCenter JS20 Type 8842

Page 1: ...unit into the rack Installed and configured Supplied 200 240 V ac to the BladeCenter unit Before installing the BladeCenter JS20 Type 8842 you should have completed the following procedures Drives Mem...

Page 2: ...ns and verify that all optional devices you installed are on the ServerProven list You can view the ServerProven list at http www ibm com pc compat Server working properly Problem solved Problem solve...

Page 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ERserver...

Page 4: ...of Limited Warranty Z125 4753 08 04 2004 on page 101 and Appendix C Notices on page 121 Second Edition September 2004 Copyright International Business Machines Corporation 2004 All rights reserved US...

Page 5: ...the blade server service processor 20 Updating and managing the system flash using Linux service aids 21 Updating the system flash using Linux 21 Verifying the system firmware levels using Linux 21 Up...

Page 6: ...ssor problems 91 Light path diagnostics overview 91 Identifying problems using the light path diagnostics 91 Light path diagnostics table 92 Recovering the system firmware code 95 Recovery of system f...

Page 7: ...125 United Kingdom telecommunications safety requirement 125 European Union EMC Directive conformance statement 125 Taiwanese Class A warning statement 126 Chinese Class A warning statement 126 Japane...

Page 8: ...vi BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 9: ...lleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Page 10: ...of the caution or danger statement in the IBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statement appear in the IBM Safety Inform...

Page 11: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Page 12: ...ium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immerse i...

Page 13: ...he device v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Cl...

Page 14: ...e device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current fro...

Page 15: ...ct a service technician Statement 13 DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions To avoid these hazards ensure that your system electri...

Page 16: ...fter handling ADVERTENCIA El contacto con el cable de este producto o con cables de accesorios que se venden junto con este producto pueden exponerle al plomo un elemento qu mico que en el estado de C...

Page 17: ...perating system v Perform basic troubleshooting of the blade server This Installation and User s Guide and other related documentation are provided in Portable Document Format PDF on v The IBM BladeCe...

Page 18: ...Center unit supports varies by the wattage of the power modules that are installed in the BladeCenter unit For more information about determining the power requirements for the blade server see the IB...

Page 19: ...adeCenter documentation will be displayed under the heading Online publications by date In addition to this Installation and User s Guide the following related documentation is available in PDF on the...

Page 20: ...ernet Switch Module for BladeCenter Installation and User s Guide This document contains instructions for setting up installing and configuring the IBM 4 Port Gb Ethernet Switch Module for BladeCenter...

Page 21: ...into your CD ROM drive then run the following command from the mnt cdrom directory sh runlinux sh Select the blade server from the Product menu The Available Topics list displays all the books for th...

Page 22: ...ou avoid inconvenient or problem situations v Attention These notices indicate potential damage to programs devices or data An attention notice is placed just before the instruction or situation in wh...

Page 23: ...ure one or two Ethernet switch modules in the BladeCenter unit To support the Serial Over LAN SOL feature on any blade server that is installed in the BladeCenter unit v A SOL compatible Ethernet swit...

Page 24: ...eceived your Type 8677 BladeCenter unit before June 2003 the customer interface card CIC in the media tray of the BladeCenter unit might need to be replaced before the CD ROM drive will work correctly...

Page 25: ...l Update v To help ensure proper cooling performance and system reliability do not operate the BladeCenter unit for more than 1 minute without a blade server or filler blade installed in each blade ba...

Page 26: ...e in the open position perpendicular to the blade server 6 Slide the blade server into the bay until it stops The spring loaded doors further back in the bay that cover the bay opening move out of the...

Page 27: ...ly through a separate client system that uses the Telnet program For additional information about SOL requirements see the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide For add...

Page 28: ...12 BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 29: ...ckages that come with the operating system For additional information see the instructions that come with your operating system documentation and the service packs or update packages v The BladeCenter...

Page 30: ...tructions will be displayed under the heading OS installation by date After you install the operating system be sure to install the ppc64 Linux utilities that apply to your operating system Instructio...

Page 31: ...ge the battery or replace the system board assembly you must reset the date and time through your operating system For information about setting up your network configuration for remote management see...

Page 32: ...s Guide v Nortel Networks Layer 2 7 GbE Switch Module for IBM BladeCenter Installation Guide v BladeCenter Management Module Command Line Interface Reference Guide v IBM Eserver BladeCenter and Blade...

Page 33: ...rd PASSW0RD note the number zero not the letter O in PASSW0RD 3 Follow the instructions that appear on the screen Be sure to set the timeout value that you want for your Web session The BladeCenter ma...

Page 34: ...r updated information about configuring the controllers go to the IBM Support Web site at http www ibm com pc support Blade server Ethernet controller enumeration The enumeration of the Ethernet contr...

Page 35: ...the open firmware prompt enter the following commands dev packages gui setup fcp disk The open firmware Main Menu appears 5 From the Main Menu select option 2 Select Media Adapter After you make this...

Page 36: ...ypes of information differ download the latest firmware code from the IBM Support Web site Follow the update instructions on the IBM Support Web site Note The firmware version displayed by the BladeCe...

Page 37: ...is will copy your new image from the TEMP side to PERM side of flash Verifying the system firmware levels using Linux To verify the system firmware levels on the PERM and TEMP sides enter the followin...

Page 38: ...or optical media put the image on the media of choice before running this service aid 2 Run diagnostics v If you have booted AIX login as root or use the CE login then at the command line enter diag...

Page 39: ...To verify levels of system firmware on the PERM and TEMP sides use the AIX diagnostics Update and Manage System Flash see Updating the system flash using AIX on page 22 The diagnostics function displ...

Page 40: ...n and instructions see the BladeCenter Management Module Command Line Interface Reference Guide Using the simple network management protocol SNMP In addition to the management module command line inte...

Page 41: ...mory modules DIMMs IDE devices v Support for up to two internal integrated drive electronics IDE 2 5 inch hard disk drives or v Support for one internal IDE 2 5 inch hard disk drive in IDE connector 1...

Page 42: ...Ethernet controller port has an interface for connecting to 10 100 1000 Mbps networks through an Ethernet compatible switch module on the BladeCenter unit The switch module automatically selects betw...

Page 43: ...vailable when you want to use it and in the event of a failure help you easily diagnose and repair the failure with minimal inconvenience The following is a list of some of the RAS features that your...

Page 44: ...eries systems_management sys_migration ibmdiragent html It is updated every 6 to 8 weeks v Support for IBM and non IBM servers desktop computers workstations and mobile computers v Support for systems...

Page 45: ...owing illustration shows the location of the system board components including connectors for user installable options Note The illustrations in this document might differ slightly from your hardware...

Page 46: ...a maximum of 25 seconds or less depending on the number of LEDs that are lit and the length of time the blade server is removed from the BladeCenter unit by pressing the light path diagnostics button...

Page 47: ...blade server control panel door to turn off the blade server You do not have to shut down the BladeCenter unit itself v Blue on a component indicates touch points where you can grip the component to r...

Page 48: ...s frame v Do not touch solder joints pins or exposed printed circuitry v Do not leave the device where others can handle and damage it v While the device is still in its static protective package touc...

Page 49: ...lade bays in the BladeCenter unit are hot swap bays Therefore you can install or remove the blade server without removing power from the BladeCenter unit However you must turn off the blade server bef...

Page 50: ...page 31 2 Carefully place the blade server on a flat static protective surface with the cover side up 3 Press the blue blade cover release on each side of the blade server and lift the cover open as s...

Page 51: ...approximately 1 2 cm 0 5 inch 4 Disconnect the control panel cable from the control panel connector 5 Pull the bezel assembly away from the blade server 6 Store the bezel assembly in a safe place Ins...

Page 52: ...ned off press the power control button behind the blade server control panel door to turn off the blade server See Blade server controls and LEDs on page 53 for more information about the location of...

Page 53: ...blade server are 256 MB 512 MB and 1 GB The blade server supports a minimum of 512 MB and a maximum of 4 GB of system memory v Both DIMMs in a pair must be the same size speed type and technology You...

Page 54: ...moving the blade server from the BladeCenter unit on page 33 for instructions 4 Carefully place the blade server on a flat static protective surface 5 Open the blade server cover See Opening the blade...

Page 55: ...is example you could then install two Ethernet switch modules two pass thru modules or one Ethernet switch module and one pass thru module Because pass thru modules are compatible with a variety of I...

Page 56: ...BladeCenter unit on page 33 for information 4 Carefully place the blade server on a flat static protective surface 5 Open the cover see Opening the blade server cover on page 34 for instructions 6 In...

Page 57: ...4 Port Gb Ethernet Switch Module for BladeCenter in I O bay 3 or 4 of the BladeCenter unit to support these additional Ethernet connections The optional Ethernet switch modules contain four ports with...

Page 58: ...465 7999 or 1 800 465 6666 within Canada Outside the U S and Canada call your IBM authorized reseller or IBM marketing representative Note After you replace the battery the blade server is automatical...

Page 59: ...lade server control panel door to turn off the blade server See Blade server controls and LEDs on page 53 for more information about the location of the power control button 4 Remove the blade server...

Page 60: ...ket under the battery clip Make sure that the side with the positive symbol is facing up b As you slide it under the battery clip press the battery down into the socket 10 Close the blade server cover...

Page 61: ...upport Center team determines that the blade server requires a replacement system board assembly they will send a replacement system board assembly to you Before you call make sure that you know the f...

Page 62: ...35 v DIMMs see Installing memory modules on page 37 v I O expansion cards and expansion card trays see Installing an I O expansion card on page 39 v Jumper J14 between jumpers J16 and J20 for location...

Page 63: ...new label on the blade server bezel assembly Also be sure to place the RID tag label on the bottom of the blade server chassis 11 Install the blade server bezel assembly on the blade server see Instal...

Page 64: ...nectors and devices on page 50 Completing the installation To complete the installation perform the following tasks if you have not already done so 1 Install the blade server bezel assembly on the bla...

Page 65: ...ollowing steps to install the blade server bezel assembly 1 Read the safety information beginning on page vii and Installation guidelines on page 31 2 Connect the control panel cable to the control pa...

Page 66: ...make sure that all components are installed and seated correctly and that you have not left loose tools or parts inside the blade server 4 Pivot the cover to the closed position as shown in the illus...

Page 67: ...ent module nonvolatile random access memory NVRAM To disable the Wake on LAN feature for one or more blade servers use the BladeCenter management module Web interface For more information about the Bl...

Page 68: ...llowing ways v You can press the power control button on the blade server behind the control panel door This starts an orderly shutdown of the operating system if this feature is supported by your ope...

Page 69: ...panel door Press this button to manually turn the blade server on or off Note The power control button has effect only if local power control is enabled for the blade server Local power control is ena...

Page 70: ...about a system error for this blade server has been placed in the BladeCenter system error log The error might not require immediate service Location LED When this blue LED is lit it has been turned o...

Page 71: ...n in the drop down list follow the instructions on the Web page to download the latest version 2 Install the IBM Director program 3 Download and install any applicable updates or interim fixes for you...

Page 72: ...56 BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 73: ...t editions of the IBM BladeCenter documentation go to http www ibm com pc support on the World Wide Web See Related documentation on page 3 for additional information Important If you cannot access th...

Page 74: ...f the server b Remove the blade server from the BladeCenter unit c Open the blade server and press and hold the light path diagnostics button See Light path diagnostics table on page 92 for the locati...

Page 75: ...ight be displayed at the same time on the second line The management module log which can be accessed through the BladeCenter unit contains the most recent error codes and messages that the system gen...

Page 76: ...mware 1 Perform the system checkout procedure See System checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for mor...

Page 77: ...s error indicates that you might have a problem with the system board Contact a service support representative for more information E102 Load and initialize the RTAS 1 Perform the system checkout proc...

Page 78: ...oot list with the management module boot list 1 Make sure that the boot list is correct using the management module boot list menu 2 Perform the system checkout procedure See System checkout on page 5...

Page 79: ...support representative for more information E152 Probe for the adapter firmware code evaluate if present 1 Perform the system checkout procedure See System checkout on page 58 2 This error indicates...

Page 80: ...correct then retry the operation 3 Perform the system checkout procedure See System checkout on page 58 4 If there are no problems with the BOOTP server or the network connection replace the system bo...

Page 81: ...system board Contact a service support representative for more information E19B NVRAM menu variable not found assume FALSE 1 Perform the system checkout procedure See System checkout on page 58 2 Thi...

Page 82: ...service support representative for more information E1A7 The user requested startup using the customized service mode boot list of the service processor command 1 Perform the system checkout procedure...

Page 83: ...page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for more information E1B2 XOFF received waiting for XON Have the blade serve...

Page 84: ...rform the system checkout procedure See System checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for more informat...

Page 85: ...rmation E199 Restarting rebooting the partition to activate the changes that are specified in the boot image s executable and linkable format ELF header 1 Check the http www ibm com pc support Web sit...

Page 86: ...flash code into Level 2 L2 cache 1 Perform the system checkout procedure See System checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service su...

Page 87: ...ou might have a problem with the system board Contact a service support representative for more information E214 Pattern 1 memory test 1 Make sure that the DIMMs are correctly installed and seated the...

Page 88: ...y 1 Perform the system checkout procedure See System checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for more in...

Page 89: ...e System checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for more information E800 Start the instantiation of RT...

Page 90: ...ystem checkout on page 58 2 This error indicates that you might have a problem with the system board Contact a service support representative for more information E875 Initialize rtas_last_error 1 Per...

Page 91: ...the server 1 Contact your network administrator to make sure that the server and gateway network are correct 2 Contact a service support representative for assistance 20A80001 The client Internet Pro...

Page 92: ...e was found in the boot list however the ibm fw fcpdisk alias name has not been defined in the alias node Type the setup fc disk command at the open firmware prompt and press Enter then restart the bl...

Page 93: ...ode on page 95 Have the blade server serviced 20D00903 The blade server failed to find the openprom package This is most likely a software error Have the blade server serviced Contact a service suppor...

Page 94: ...rm the system checkout procedure See System checkout on page 58 20EE0016 The blade server failed to update the VPD with the new startup path field value 1 Make sure that the boot list in the managemen...

Page 95: ...p www ibm com pc support Web site for firmware updates for the management module service processor and blade server Apply the latest updates if they are available 3 If updates are not available contac...

Page 96: ...e system board assembly Contact a service support representative for assistance 21020015 The USB CD ROM drive failure of ATA or ATAPI packed command processing by USB CD ROM drive 1 If the problem rem...

Page 97: ...remains replace the system board assembly Contact a service support representative for assistance 25A00001 Level 2 L2 cache controller failure Replace the system board assembly Contact a service supp...

Page 98: ...able If the problem remains replace the battery in the blade server For additional information see Replacing the battery on page 42 Note After you replace the battery you must reset the system date an...

Page 99: ...valuation error Perform the following steps to remove the NVRAMRC script 1 Boot to the open firmware prompt 2 Enter the following command 0 0 nvramrc setenv If the problem remains contact your system...

Page 100: ...DIMM4 failed 88 DIMM3 and DIMM4 mismatch Note For additional information about DIMMs see Installing memory modules on page 37 1 Make sure that all the DIMMs in the blade server are supported Replace...

Page 101: ...DIMMs 2 Make sure that the DIMMs are installed in matched pairs If the DIMMs are not installed in matched pairs reinstall them in matched pairs 3 Make sure that the DIMMs are correctly seated If neces...

Page 102: ...replace the system board assembly Contact a service support representative for assistance 2803000A The Hypervisor function to get or set the time of day TOD reported an error Errors that are reported...

Page 103: ...ata storage interrupt DSI 4 Instruction storage interrupt ISI 5 External interrupt EXI 6 Alignment interrupt ALI 7 Program interrupt SRI 8 Floating unavailable interrupt FUI Complete the following ste...

Page 104: ...with the device for more information CD ROM drive problems Symptom Suggested action The BladeCenter JS20 Type 8842 cannot access the CD ROM drive in the BladeCenter unit 1 Important If you are using...

Page 105: ...e server remove it and restart the blade server If the blade server now turns on troubleshoot the option see the documentation that comes with the option for information 3 Try another blade server in...

Page 106: ...mation about obtaining ServerProven compatibility information from the World Wide Web v You followed the installation instructions that came with the option v You have not loosened any other installed...

Page 107: ...tion provides the information to identify using the light path diagnostics problems that might arise during installation To locate the actual component that caused the error you must locate the lit er...

Page 108: ...removed from the BladeCenter unit by pressing the light path diagnostics button SW1 v Error LED CR29 is not used v For the locations of the corresponding dual inline memory module DIMM sockets and mic...

Page 109: ...ity two microprocessors and two heat sinks are required on the system board in the blade server at all times The microprocessors and heat sinks on the system board are not replaceable Therefore if a m...

Page 110: ...restart the server If the problem remains have the blade server serviced Processor x phase locked loop PLL error The microprocessor circuit is defective and cannot process the required signals Attent...

Page 111: ...tem Users can install these free diagnostics tools for effective diagnosis and repair of the system in the rare instance when a system error occurs This service aid toolkit provides the key tools requ...

Page 112: ...rom the PERM image you must perform the reject function The reject function copies the PERM image into the TEMP image To perform the reject function complete the following steps 1 If you have not star...

Page 113: ...e blade server is connected to the power source Always replace the blade cover before installing the blade server g Restart the blade server h Verify that the system starts from the TEMP image v If yo...

Page 114: ...98 BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 115: ...e assistance by following the troubleshooting procedures that IBM provides in the online help or in the documentation that is provided with your system and software The information that comes with you...

Page 116: ...elliStation workstations and appliances For information about which products are supported by Support Line in your country or region go to http www ibm com services sl products For more information ab...

Page 117: ...removal of parts and their return to IBM A part that replaces a removed part will assume the warranty service status of the removed part Unless IBM specifies otherwise these warranties apply only in...

Page 118: ...Machine and other software updates from an IBM Internet Web site or from other electronic media and following the instructions that IBM provides If your problem can be resolved with a Customer Replace...

Page 119: ...mage to your Machine only while it is 1 in IBM s possession or 2 in transit in those cases where IBM is responsible for the transportation charges Neither IBM nor your reseller are responsible for any...

Page 120: ...WHICH VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION Jurisdiction All of our rights duties and obligations are subject to the courts of the country in which you acquired the Machine Part 2 C...

Page 121: ...Asuncion PERU Limitation of Liability The following is added at the end of this section In accordance with Article 1328 of the Peruvian Civil Code the limitations and exclusions specified in this sect...

Page 122: ...es to right to sell quiet possession or clear title or the goods are of a kind ordinarily acquired for personal domestic or household use or consumption then none of the limitations in this paragraph...

Page 123: ...is the subject of the claim For purposes of this item the term Machine includes Machine Code and Licensed Internal Code LIC Arbitration The following is added under this heading Disputes arising out o...

Page 124: ...rst sentence laws of the State of New York United States of America except when local law requires otherwise PHILIPPINES Limitation of Liability Item 3 in the fifth paragraph is replaced by the follow...

Page 125: ...ope countries provided the Machines have been announced and made available in such countries If you purchase a Machine in one of the Western European countries as defined above you may obtain warranty...

Page 126: ...babwe all disputes arising out of this Statement of Limited Warranty or related to its execution including summary proceedings will be submitted to the exclusive jurisdiction of the English courts 3 i...

Page 127: ...595 1 figure 7 of the Code IBM may however institute proceedings in a competent court in the country of installation In Estonia Latvia and Lithuania all disputes arising in connection with this Statem...

Page 128: ...Y ARISE AS AN IMMEDIATE CONSEQUENCE OF THE EVENT THAT GENERATED THE DAMAGES OR 4 LOSS OF BUSINESS REVENUE GOODWILL OR ANTICIPATED SAVINGS FRANCE AND BELGIUM Limitation of Liability The following repla...

Page 129: ...or the transportation charges for the delivery of the failing Machine to IBM Limitation of Liability The following paragraph is added to this section The limitations and exclusions specified in the St...

Page 130: ...mitation of Liability The following paragraph is added to this section The limitations and exclusions specified in the Statement of Limited Warranty will not apply to damages caused by IBM with fraud...

Page 131: ...sets out the extent of IBM s liability and your sole remedy 1 IBM will accept unlimited liability for death or personal injury caused by the negligence of IBM 2 Subject always to the Items for Which...

Page 132: ...l injury caused by the negligence of IBM and b any breach of its obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2 of the Supply of Goods and Services Act 1982 or any statut...

Page 133: ...eseller if approved by IBM to perform warranty service Scheduling of service will depend upon the time of your call and is subject to parts availability Service levels are response time objectives and...

Page 134: ...changed the Machine IBM will make it available for your collection or for Mail in Service IBM will return it to you at IBM s expense unless IBM specifies otherwise You are responsible for the subseque...

Page 135: ...ing Austria 43 1 24592 5901 Latvia 386 61 1796 699 Belgium 32 70 23 3392 Lithuania 386 61 1796 699 Cyprus 357 22 841100 Luxembourg 352 298 977 5063 Czech Republic 420 2 7213 1316 Malta 356 23 4175 Den...

Page 136: ...120 BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 137: ...TY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Page 138: ...Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other co...

Page 139: ...bility and fitness for a particular purpose These products are offered and warranted solely by third parties IBM makes no representations or warranties with respect to non IBM products Support if any...

Page 140: ...tices Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These li...

Page 141: ...J 100003 for indirect connection to public telecommunication systems in the United Kingdom European Union EMC Directive conformance statement This product is in conformity with the protection requirem...

Page 142: ...Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement 126 BladeCenter JS20 Type 8842 Installation and User s Guide...

Page 143: ...IBM power cord part number Used in these countries and regions 02K0546 China 13F9940 Australia Fiji Kiribati Nauru New Zealand Papua New Guinea 13F9979 Afghanistan Albania Algeria Andorra Angola Armen...

Page 144: ...muda Bolivia Brazil Caicos Islands Canada Cayman Islands Costa Rica Colombia Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Japan Mexico Micronesia Federal States of...

Page 145: ...ing 46 removing 46 system board 29 configuration automatic 15 command line interface 24 Ethernet controller 17 18 Fibre Channel boot 19 configuration continued management module program 17 Serial Over...

Page 146: ...d installing 39 location 40 network interface requirements 39 IBM Director 26 28 55 identifying problems light path diagnostics 91 memory 89 network connection 90 options 90 power 89 service processor...

Page 147: ...tem firmware levels 21 Serial Over LAN SOL requirements 13 service packs 13 update packages 13 option expansion cards 39 hard disk drives 35 identifying problems 90 installing 31 option continued memo...

Page 148: ...system board assembly 46 troubleshooting charts 88 overview 57 turning off the blade server 52 turning on the blade server 51 U United States electronic emission Class A notice 124 United States FCC...

Page 149: ......

Page 150: ...Part Number 25K8416 Printed in USA 1P P N 25K8416...

Reviews: