Table 14. A700yyyy Licensed internal code SRCs (continued)
Reference Code
Description
Action
A7004721
The World Wide Port Name (WWPN) Prefix is
not valid.
https://www-912.ibm.com/supporthome.nsf/
document/51455410
A7004730
Informational system log entry only.
No corrective action is required.
A7004740
Informational system log entry only.
No corrective action is required.
A7004741
Informational system log entry only.
No corrective action is required.
A7004788
Informational system log entry only.
No corrective action is required.
A70047FF
Informational system log entry only.
No corrective action is required.
A7013003
Partition-initiated PHYP-content RSCDUMP.
No corrective action is required.
A700yyyy
For any other A7xxyyyy SRC not listed here,
see the description for the B7xxyyyy error code
with the same
xxyyyy
value.
Perform the action in the B7xxyyyy error code
with the same
xxyyyy
value.
AA00E1A8 to AA260005 Partition firmware attention codes
AAxx attention codes provide information about the next target state for the platform firmware. These
codes might indicate that you need to perform an action.
Table 15 describes the partition firmware codes that might be displayed if the POST detects a problem.
Each message description includes a suggested action to correct the problem.
Table 15. AA00E1A8 to AA260005 Partition firmware attention codes
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, type 7891,” on page 225 to determine which components are CRUs and which
components are FRUs.
Attention code
Description
Action
AA00E1A8
The system is booting to the open
firmware prompt.
At the open firmware prompt, type
dev
/packages/gui obe
and press
Enter
; then, type
1
to select
SMS Menu
.
AA00E1A9
The system is booting to the System
Management Services (SMS) menus.
1.
If the system or partition returns to the
SMS menus after a boot attempt failed, use
the SMS menus to check the progress
indicator history for a
BAxx xxxx
error,
which may indicate why the boot attempt
failed. Follow the actions for that error code
to resolve the boot problem.
2.
Use the SMS menus to establish the boot
list and restart the blade server.
AA00E1B0
Waiting for the user to select the
language and keyboard. The menu
should be visible on the console.
1.
Check for server firmware updates.
2.
Apply any available updates.
3.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
Chapter 2. Diagnostics
37