Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
103-151
151
The time-of-day battery failed.
1.
Go to “Removing the battery” on page 258 to start the battery replacement
procedure.
2.
Go to “Installing the battery” on page 258 to complete the procedure.
109-200
The system crashed while you running it.
1.
Go to “Performing the checkout procedure” on page 177.
2.
If the 8-digit error and location codes were NOT reported, run AIX diagnostics in
problem determination procedure and record and report the 8-digit error and
location codes for this SRN.
110-101
The diagnostics did not detect an installed resource. If this SRN appeared when
running concurrent diagnostics, then run concurrent diagnostics using the diag -a
command.
110-921 to
110-926
812 xxx
The system halted while diagnostics were executing.
Go to “Performing the checkout procedure” on page 177 or problem resolution.
Note:
xxx corresponds to the last three digits of the SRN.
110-935
812
The system halted while diagnostics were executing. Use the problem determination
procedure.
110-xxxx
xxxx 221
The system halted while diagnostics were executing.
Note:
xxxx corresponds to the last three or four digits of the SRN following the dash
(-).
1.
If your 110 SRN is not listed, substitute the last three or four digits of the SRN for
xxxx and go to “Failing function codes” on page 173 to identify the failing feature.
2.
Run stand-alone diagnostics and the problem determination procedure for your
operating system.
111-107
A machine check occurred. Go to “Performing the checkout procedure” on page 177.
111-108
An encoded SRN was displayed. Go to “Performing the checkout procedure” on page
177.
111-121
There is a display problem. Go to “Performing the checkout procedure” on page 177.
111-78C
227
PCI adapter I/O bus problem. Go to “Performing the checkout procedure” on page
177. Perform “Solving undetermined problems” on page 223.
111-999
210
System does not perform a soft reset. Go to “Performing the checkout procedure” on
page 177.
650-xxx
650
Disk drive configuration failed.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Update the disk drive firmware.
4.
Troubleshoot the disk drive.
5.
Replace the system-board
651-140
221
Display Character test failed.
Note:
Diagnostic will provide this SRN but there is no action to be taken. Do not
perform operator panel test from diagnostics.
Chapter 2. Diagnostics
143