Table 16. B2xxyyyy Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, type 7891,” on page 225 to determine which components are CRUs and which
components are FRUs.
Reference Code
Description
Action
B2002048
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
Go to “Isolating firmware problems” on page 216.
B2002054
A problem occurred during a
partition Main Storage Dump. A
mainstore dump IPL did not
complete due to a configuration
mismatch.
Go to “Isolating firmware problems” on page 216.
B2002058
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
Go to “Isolating firmware problems” on page 216.
B2002210
Informational system log entry only.
No corrective action is required.
B2002220
Informational system log entry only.
No corrective action is required.
B2002250
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002260
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2002300
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002310
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2002320
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2002425
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2002426
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2002475
During the startup of a partition, a
slot that was needed for the partition
was either empty or the device in
the slot has failed.
Check for server firmware updates; then, install the
updates if available.
B2002485
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 216.
B2003000
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
43