SMBUS Error (3-3-2)
Note
The minimum system configuration required to force
power-on the system using I/O board jumper J7 is:
One bank of memory on one memory card with
terminator
One processor with two VRMs and terminator
card
One power supply
If the system displays a 3-3-2 error and powering off,
waiting for 20 seconds; then, powering on the system does
not correct the problem, do the following:
1. Connect remotely to the system and check the
system error log.
2. Remove the system management card.
3. Disconnect the front panel cable form the I/O function
card.
4. Disconnect the SCSI power cable.
5. Remove/disable all adapters.
6. Use jumper J7 on the I/O board to power-on the
server.
7. If the server starts, attach/install the components one
at a time in the following order, until you isolate the
failing FRU.
a. Front Panel to I/O Card Cable
b. System Management Card
c. SCSI Power Cable
d. Adapter cards, one at a time.
8. If the server does not start with the minimum required
configuration, replace the following FRUs in the order
listed.
a. Power Control Card
b. Processor Board
c. I/O Board
d. Power Backplane
e. I/O Function Card
204
Netfinity Server HMM
Summary of Contents for 86803RU - Netfinity 7000 M10
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 110: ...1 5 6 9 102 Netfinity Server HMM...
Page 232: ...224 Netfinity Server HMM...
Page 249: ...Related Service Information 241...
Page 250: ...242 Netfinity Server HMM...
Page 251: ...Related Service Information 243...
Page 252: ...244 Netfinity Server HMM...
Page 253: ...Related Service Information 245...
Page 266: ...258 Netfinity Server HMM...
Page 267: ...Related Service Information 259...
Page 268: ...260 Netfinity Server HMM...
Page 278: ...IBM Part Number 09N1052 Printed in U S A S 1K 4643 2...