v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
BMC
log
message
Sensor
number
Sensor
type
Action
VRD
3
status
Assertion
00
(Presence
detected)
26
08
Information
only
VRD
3
status
Assertion
01
(Power
unit
failure)
26
08
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
(Trained
service
technician
only)
Replace
the
microprocessor.
VRD
4
status
Assertion
00
(Presence
detected)
27
08
Information
only
VRD
4
status
Assertion
01
(Power
unit
failure)
27
08
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
(Trained
service
technician
only)
Replace
the
microprocessor.
VRD
5V
Assertion
00
(Presence
detected)
28
08
Information
only
VRD
5V
Assertion
01
(Power
unit
failure)
28
08
1.
Remove
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time
to
isolate
the
failing
component:
a.
Keyboard,
mouse,
and
USB
devices
b.
DASD
devices
c.
PCI
adapters
d.
DVD
drive
2.
If
the
problems
remains:
a.
Inspect
the
SAS
power
cable
and
the
IDE
power
cable.
b.
Inspect
the
front
panel
USB
cable.
c.
(Trained
service
technician
only)
Replace
the
system
board.
VRD
3.3V
Assertion
00
(Presence
detected)
29
08
Information
only
VRD
3.3V
Assertion
01
(Power
unit
failure)
29
08
1.
Remove
the
PCI
adapters
one
at
a
time,
to
isolate
the
failing
component.
2.
Inspect
the
IDE
power
cable.
3.
(Trained
service
technician
only)
Replace
the
system
board.
4.
Replace
the
SAS
backplane
assembly.
78
IBM
System
x3655
Type
7985
and
7943:
Problem
Determination
and
Service
Guide
Summary of Contents for 7985
Page 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 112: ...View 1...
Page 159: ...Battery Chapter 5 Removing and replacing server components 141...
Page 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 217: ......
Page 218: ...Part Number 42D2167 Printed in USA 1P P N 42D2167...