Off Line Diagnostic Error Codes
D-27
1010
Fan 2 fault
1011
Fan 3 fault
1100
Fan 4 fault
1100
Fan 5 fault
1100
Fan 6 fault
1111
Reserved
Power Up
Bits 4–6 Values
Description
000
Manual On button pushed
001
Remote On signal from external
010
Timed power on from TOD clock
011
Remote on signal from power control interface
100
Automatic restart
Power Up
Bit 7 Values
Description
0
No thermal warning
1
Thermal warning
Battery Status
Bit 8 Values
Description
0
Backup battery not installed
1
Backup battery installed
Battery Status
Bit 9 Values
Description
0
Backup battery OK (if installed)
1
Backup battery discharged or failing
Power Interrupt (Action for rc.powerfail)
Bits 10–13 values
Description
0000
No action
0001
WARN_COOLING no reaction
0010
WARN_POWER error logging
0011
Severe cooling problem, SLOW_SHUTDOWN 10 minutes to
shutdown
0100
Very severe cooling problem, FAST_SHUTDOWN 20 sec to
shutdown
0101
IMMED_SHUTDOWN immediate power down