Service Guide
D-6
Error
Number
Source
Failing
Function
Codes
Failure
Percent
(%)
Description
401-514
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
APR register error.
Action: Use MAP 0210.
401-515
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
BSR init value.
Action: Use MAP 0210.
401-516
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
MD0 init value.
Action: Use MAP 0210.
401-517
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
MD1 init value.
Action: Use MAP 0210.
401-518
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
XIVR6 init value.
Action: Use MAP 0210.
401-519
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
DSIER init value.
Action: Use MAP 0210.
401-520
K
C59
100
Description: Direct IO. IONIAN register access error.
Action: Use MAP 0210.
401-521
K
C59
C61
80
20
Description: Direct IO. SSGA POS register error.
Action: Use MAP 0210.
401-522
K
C59
C61
80
20
Description: Direct IO. SSGA interrupt register error.
Action: Use MAP 0210.
401-523
K
C59
C90
MCA
adapters
25
25
50
Description: Direct IO: IONIAN-SSGA. IER register error on Base
Unit.
Action: Use MAP 0210.
401-524
K
C59
C90
MCA
adapters
25
25
50
Description: Direct IO: IONIAN-SSGA. IER register error on Base
Unit.
Action: Use MAP 0210.
401-530
K
C59
C61
80
20
Description: Direct IO. NVRAM data lines access error.
Action: Use MAP 0210.
401-531
K
C59
C61
80
20
Description: Direct IO. NVRAM address lines access error.
Walking 1 phase.
Action: Use MAP 0210.
401-532
K
C59
C61
80
20
Description: Direct IO. NVRAM address lines access error.
Walking 0 phase.
Action: Use MAP 0210.
401-540
K
C59
C61
80
20
Description: Direct IO. Super IO UART1 access error.
Action: Use MAP 0210.
401-541
K
C59
C61
80
20
Description: Direct IO. Super IO UART2 access error.
Action: Use MAP 0210.
401-542
K
C59
C61
80
20
Description: Direct IO. 16550 UART access error.
Action: Use MAP 0210.
401-543
K
C59
C61
80
20
Description: Direct IO. Floppy disk access error.
Action: Use MAP 0210.
401-544
K
C59
C61
80
20
Description: Direct IO. BPP register access error.
Action: Use MAP 0210.
Summary of Contents for 7012 G Series
Page 1: ...7012 G Series Service Guide...
Page 6: ...vi Service Guide...
Page 10: ...x Service Guide...
Page 98: ...3 1520 8 Service Guide...
Page 183: ...7 2 Service Guide Covers and Chassis 4 8 9 2 3 1 18 7 14 15 12 13 10 11 16 17 5 6...