3-1540-3
Maintenance Analysis Procedures (MAPs)
Note: Before verifying any condition indicated in the following steps of this MAP (for
example, a certain code displayed on the operator panel display), be sure that the
system activity has stopped on that condition (same condition for more than 3
minutes except for
165
, which may display up to ten minutes with no activity on the
BUMP console).
Information in
operator panel
display
Other conditions
Do this:
Blank
Diagnostic Operating Screen is displayed.
Go to Step 10.
Blank
Maintenance Menu is displayed.
Select
System
Boot,
then
Boot
From List
(CD-ROM). Wait for one
of the other symptoms in
this table to occur.
888
flashing
With same SRN or a Crash Code
Go to Step 2.
888
flashing
With new SRN
Record the SRN. Look up
the SRN in the SRN Table
and do the listed action.
260
Main Menu is Displayed
Select
Exit Main Menu
and Start System
(Boot)
then press
En-
ter.
When the
Start-
ing System Boot
menu displays, press
En-
ter.
Note:
Repeat this pro-
cedure each time these
conditions occur.
269
flashing
Go to Step 20.
269
solid
Go to Step 19.
c31
Instructions to select the system console
are displayed on the screen.
Follow the instructions on
the screen. Wait for one
of the other symptoms in
this table to occur.
325
or less
Digits are on solid for more than 3 minutes,
except for
165
which may display up to ten
minutes with no activity on the BUMP con-
sole, and the Power light is on.
Go to Step 2.
326
or greater
Digits are on solid for more than 3 minutes,
the Power light is on, and the diagnostic
CD is loaded.
Go to Step 7.
Any symptom not listed above.
Go to Step 2.