Service Guide
D-26
Error Logging
When a failure occurs on a fan or on a power supply, the system produces a logging report
for this event. The logging report can be viewed using
errpt.
An
errpt report about power and fan is the following:
LABEL: EPOW_SUS
Description: LOSS OF ELECTRICAL POWER
Probable Causes: POWER SUBSYSTEM
INTERNAL POWER UNIT
Failure Causes: POWER SUBSYSTEM
RECOMMENDED ACTIONS: CHECK POWER
POWER STATUS REGISTER:
9005 0007
The Power/Keylock Status Register has the following format:
PKSR Layout
0..3 4.6 7 8 9 10..13 14 15 16......23 24..27 28..31
Keylock position
Reserved for future use
Power fault and fan fault decode (R Series only)
Action bits for rc.powerfail
Battery backup Status (not used)
Battery backup plug (not used)
Power interrupt and fan fault decode (G Series and J Series only)
Cooling system operating in backup mode
Power system operating in backup mode
Power up decode
Power up decode
Bit Numbering
Power Interrupt and Fan Fault (G Series and J Series only)
Bits 0–3 values
Description
0000
No Interrupt
0001
Running on battery
0010
Programmed Power Off
0011
manual switch off
0100
Remote power off
0101
Over temperature level 1
0110
Internal power supply failure
0111
Power supply overload
1000
Loss of Primary power (EPOW)
1001
Fan 1 fault