SAN16M-R SAN Router Installation And Service Manual
28
Cable guidelines
ATTENTION!
Review and implement the following cable guidelines to
avoid signal interference or cable damage.
• Use RJ45 cable for the Network Management port.
• Use DB9 null modem cable for the console port.
• Confirm you have appropriate cables to attach the devices, for
example the server and targets.
• Do not bend fiber optic cables to a radius smaller than three (3)
inches. Doing so could result in serious degradation in
performance or complete loss of connectivity.
• Do not lay copper cables near transformers or alongside power
cables for any distance. Doing so could introduce noise into the
signaling.
• Avoid laying cables near sharp edges or where objects or other
equipment can crush them.
• Laser types at each end of any link must match.
Table 12
Compatible cable types
Type of Cable
Range
SFP Type
62.5 um Multi-Mode Fiber Optic
FC/GE
2-300 m
Short wave
laser
50 um Multi-Mode Fiber Optic
FC/GE
2-500 m
Short wave
laser
9 um Single Mode Fiber Optic
2m-10 Km
Long wave
laser
Copper
0-30 m (equalized cable)
0-10 m (unequalized cable)
Copper (FC
HSSDC2)
Summary of Contents for 2027-R04
Page 2: ......
Page 8: ...SAN16M R SAN Router Installation And Service Manual vi...
Page 10: ...SAN16M R SAN Router Installation And Service Manual viii...
Page 12: ...SAN16M R SAN Router Installation And Service Manual x...
Page 36: ...SAN16M R SAN Router Installation And Service Manual 12...
Page 98: ...SAN16M R SAN Router Installation And Service Manual 74...
Page 115: ......
Page 116: ...Printed in USA GC26 7744 02...