2.7. CHANGING THE BOILER WATER
• Disconnect the machine by setting the switch (12) to the off position.
• Open the steam knobs (7) until no more steam comes out. (Use the steam dispensers (9) with care, as
during normal operations they are extremely hot).
• Close the steam knobs (7).
• Open the drain valve (25) until the boiler is completely empty.
• Close the drain valve (25).
• Connect the machine, setting the switch (12) to position 1 (or switch (22) to ON) and wait until the
automatic control system completes the filling of the boiler from the mains water supply.
2.8. WATER SOFTENING (NOT INCLUDED)
The water softener removes lime from the water supply, preventing the formation of deposits and scale.
The water softener deteriorates with continuous use, and must be cleaned periodically or replaced. This process must
return the softener to its original condition. The presence of lime scale in the boiler due to an oversight of this process will
render any manufacturer’s guarantee void. (The water softener is not included.)
2.9. DISPLAY OPERATION (OPTIONAL)
2.9.1. New Iberital display
OK
MENU
I
0
5
4
1
2
3
1. ON/OFF
2. DOWN
3. UP
4. MENU
5. OK
2.9.2. TFT display screen Iberital Expression Pro (touchscreen)
102ºC
13:34
2.9.3. Display features
2.9.3.1. LCD display screen (non-touchscreen)
The display versions have two lines with 16 characters on each.