COUNTERS
: Through this menu we can see all the counters.
0 0
0
1
Group 1
Group 2
Group 3
Others
By pressing the
icon, we can select the group for which we wish
to see the counters.
Group X
quantities:
1 espresso:
1 coffee:
2 espressos:
2 coffees:
Continuous:
00000
00000
00000
00000
00000
Once a group is selected, we will see all the count values for the
group, by service type.
Other
counters:
Total erogated coffees:
Hot water:
Number of cycles:
Consumed water (l):
00000
00000
00000/00000
00000/00000
If we select the "Other" value, we can see all the general counters.
Partial counters
reset completed.
This screen shows us that we have reset the partial counters
on our machine.
IMPORTANT
The partial counters are all those relating to the making of coffee, and hot water for infusions.
To erase them, press the buttons for "2 coffees and 2 espressos" for GROUP 1 (on the left)
simultaneously, when in any counter menu screen. (The number of cycles and water consumed will
be reset by the technician after the service resets and/or filter regeneration).
-
AUTO-WASH
: Through this menu we can see the service counters.
Group 1
Group 2
Group 3
All
By pressing the
icon we can select a group, or all of them, in
order to perform an individual or collective auto-wash.
Is the cleaning filter
with detergent
put in Group X?
With the group or groups selected, we need to confirm the auto-
wash, having previously fitted the blind filters.
The temperature in
boiler is less than
70ºC (158ºF).
¿Continue anyway?
When the temperature is insufficient, we will be informed via
a message. We can continue, or go back and perform this
function, having increased the system temperature.
Auto wash in process.
Please wait.
GR. 1
GR. 2
GR. 3
Auto-wash in progress notification message.
Finished.
Please remove the cleaning filter.
GR. 1
GR. 2
GR. 3
Once the process is complete, change the filter
basket(s), and press
to quit.
2.9.3.2.2. Technical menu display
Display config.
Machine & Boiler
Config.
Doses Config.
Alarms Config.
Cancel o Go Back