Manual
ibaBM-DP
76
Issue 1.7
10.3.2.3 "Digital" tab
Fig. 44: "Sniffer" module – "Digital" tab
Enter here the digital signals you want to record in sequential order. The columns in the
signal list have the following meaning:
Name
Here, you can enter a signal name and additionally two comments, if you click on
the icon in the signal name field.
Slave
Enter the slave address that is assigned to the signal. Here, you can enter third
party slaves that are present on the bus line and as well as active slaves on the de-
vice.
I/O
Select the I/O type of the signal:
In:
Input signal from the master´s perspective
Out:
Output signal from the master´s perspective
Status:
Displays the status of the slave defined as "Slave"
(TRUE: Slave is OK, FALSE: Slave is not OK).
Active bus:
Only relevant in redundancy mode
(see chapter 12)
Service:
Only for service purposes in support cases
Address
The byte address of the signal within the input or output data range of the slave.
The address range always begins with the address 0.
Bit No.
Please enter here the Bit number within the Byte defined as "address".
Active
If this option is selected, the signal is acquired and is also considered when check-
ing the number of licensed signals.
More columns can be displayed or hidden, using the context menu (right mouse-click
on the header).