1.4.6
Specifications of EtherNet/IP Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3)
Baud Rate
10BASE-T/100BASE-T (Autonegotiation setting is recommended)
Communication Cable Length
Follows EtherNet/IP specifications (Distance between hub and each node: 100m
max.)
Number of Connection
Master Unit
Available Node Addresses for Setting 0.0.0.0 to 255.255.255.255
Communications Cable
(Note 1)
Category 5e or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 1pc
Note 1 Prepare separately for the communication cable.
1.4.7
Specifications of EtherCAT Interface
Item
Specification
Communication Protocol
IEC61158 type 12
Physical Layer
100Base-TX (IEEE802.3)
Baud Rate
Automatically follows the master
Communication Cable Length
Follows EtherCAT® specifications (Distance between each node: 100m max.)
Slave Type
I/O slave
Available Node Addresses for Setting 0 to 127 (17 to 80: When connected to the master (CJ1W-NC*82) manufactured by
OMRON)
Communications Cable
(Note 1)
Category 5e or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 2pcs (Input × 1, Output × 1)
Connect
Daisy chain only
Note 1 Prepare separately for the communication cable.