3.10 Status LED
188
3) For Fieldbus Type CC-Link
SYS
EMG MODE
T C ERR
RUN ERR
{
: Illuminating, ×: OFF,
ڏ
: Flashing
Symbol
Lamp
Condition
Color
Description
Green Ready
Orange Alarm generated
SYS
(System status)
×
–
Power is OFF or in initializing
Red
Emergency stop
EMG
(Emergency stop
status)
×
–
Normal
Green AUTO Mode
MODE
(AUTO/MANU status)
×
–
MANU Mode
Orange Controller internal communication error
T ERR
(Controller internal
communication status)
×
–
Normal
Orange Fieldbus communication error
C ERR
(Fieldbus
communication status)
×
–
Normal
Orange An error occurs. (CRC error, station No. setting
error or baud rate setting error)
ڏ
Orange Station number or baud rate changed after the
power-on
ERR
×
–
Normal
RUN
Green Communication in normal condition
Summary of Contents for Msep
Page 1: ...MSEP Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 244: ...Chapter 6 Troubleshooting 236 ...
Page 290: ...Chapter 7 Appendix 282 ...
Page 294: ......
Page 295: ......