Chapter 5 I/O Parameter
212
[21] Zone 1+, Zone 1- (Parameter No.21, No.22)
Zone 2+, Zone 2- (Parameter No.23, No.24)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
21 Zone 1+
ZONM
mm
[deg] -9999.99 to 9999.99
Actual stroke on
+ side
22 Zone 1-
ZONL1
mm
[deg] -9999.99 to 9999.99
Actual stroke on
- side
23 Zone 2+
ZNM2
mm
[deg] -9999.99 to 9999.99
Actual stroke on
+ side
24 Zone 2-
ZNL2
mm
[deg] -9999.99 to 9999.99
Actual stroke on
- side
Set the area where thzone signals (ZONE1 and ZONE2) turn ON.
The minimum setting unit is 0.01mm [deg].
If a specific value is set to both zone s and zone setting -, the zone signal is not
output.
A setting sample is shown below.
[Example of linear axis]
0mm
30mm
70mm
ON
ON
ON
100mm
Current Position
Zone signal output
Zone signal output
Set Value
Zone s : 70mm
Zone setting - : 30mm
Set Value
Zone s : 30mm
Zone setting - : 70mm
Caution: The signal cannot be output unless the range of the zone detection is set to a value
greater than that of the minimum resolution (actuator lead length/encoder resolution).
[22] PIO inch distance (Parameter No.25)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
25 PIO inch distance
IOID
mm
0.01 to 1.00
0.1
The inching distance to the inching input command from PLC is set.
(Note) The maximum allowable value is 1 mm.