Chapter 2 Wiring
40
Operation Pattern
0
1
2
3
4
5
6
Category
PIO
Functions
Point-to-Point
Movement
Movement speed
setting
Target position
change
2-Input,
3-Point
Movement
3-Input,
3-Point
Movement
Continuous
reciprocating
operation
Fieldbus
connection
Pin
No.
Solenoid
system
Single Double Single Double Single Double
–
Double
–
B1
–
COM
24V
B2
IN0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ASTR
B3
IN1
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
ST1
(Note 1)
ST1
(Note 1)
*STP
B4
IN2
RES
SPDC(RES)
(Note 2)
CN1(RES)
(Note 2)
RES
ST2(RES)
(Note 2)
RES
B5
Input
(Axis
No.4)
IN3
–/SON
–/SON
–/SON
–/SON
–/SON
–/SON
B6
IN0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ASTR
B7
IN1
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
ST1
(Note 1)
ST1
(Note 1)
*STP
B8
IN2
RES
SPDC(RES)
(Note 2)
CN1(RES)
(Note 2)
RES
ST2(RES)
(Note 2)
RES
B9
Input
(Axis
No.5)
IN3
–/SON
–/SON
–/SON
–/SON
–/SON
–/SON
B10
IN0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ASTR
B11
IN1
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
ST1
(Note 1)
ST1
(Note 1)
*STP
B12
IN2
RES
SPDC(RES)
(Note 2)
CN1(RES)
(Note 2)
RES
ST2(RES)
(Note 2)
RES
B13
Input
(Axis
No.6)
IN3
–/SON
–/SON
–/SON
–/SON
–/SON
–/SON
B14
IN0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ASTR
B15
IN1
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
*STP
ST1
(Note 1)
ST1
(Note 1)
ST1
(Note 1)
*STP
B16
IN2
RES
SPDC(RES)
(Note 2)
CN1(RES)
(Note 2)
RES
ST2(RES)
(Note 2)
RES
B17
Input
(Axis
No.7)
IN3
–/SON
–/SON
–/SON
–/SON
–/SON
–/SON
B18
OUT0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
B19
OUT1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
B20
OUT2
HEND/SV
HEND/SV
HEND/SV
HEND/SV
LS2/PE2
LS2/PE2
B21
Output
(Axis
No.4)
OUT3
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
B22
OUT0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
B23
OUT1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
B24
OUT2
HEND/SV
HEND/SV
HEND/SV
HEND/SV
LS2/PE2
LS2/PE2
B25
Output
(Axis
No.5)
OUT3
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
B26
OUT0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
B27
OUT1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
B28
OUT2
HEND/SV
HEND/SV
HEND/SV
HEND/SV
LS2/PE2
LS2/PE2
B29
Output
(Axis
No.6)
OUT3
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
B30
OUT0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
B31
OUT1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
B32
OUT2
HEND/SV
HEND/SV
HEND/SV
HEND/SV
LS2/PE2
LS2/PE2
B33
Output
(Axis
No.7)
OUT3
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
*ALM/SV
Refer to 3.4
Fieldbus
Type
Address
Map
B34
–
COM
0V
(Note) Change the output and class considering the initial setting.
[Refer to [Step 5] in 3.2 Initial Setting for the settings, and 3.8.2 Fieldbus SEP I/O Mode and PIO Operation for the
details of the signals.]
Note 1 It is invalid before home-return operation.
Note 2 The description in the brackets shows the condition before the home return operation.
(Reference) Signal of Active Low
Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input
signal is processed when it is turned OFF, output signal is ordinary on while the power is ON, and
turns OFF when the signal is output.
Summary of Contents for Msep
Page 1: ...MSEP Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 244: ...Chapter 6 Troubleshooting 236 ...
Page 290: ...Chapter 7 Appendix 282 ...
Page 294: ......
Page 295: ......