Chapter 2 Wiring
68
6) MECHATROLINK Type
Connector Name MECHATROLINK Connector
Cable Side
Prepare a connector complied with MECHATROLINK
standards.
Controller Side
DUSB-ARB82-T11A-FA
Produced by DDK
Pin No. Signal Name
Description
Applicable cable
diameter
A1/B1 NC
Disconnected
A2/B2 /DATA
Signal line - side
A3/B3 DATA
Signal line + side
Front view of
connector on
controller side
A4/B4 SH
Shield
MECHATROLINK
Dedicated Cable
Note Connect a terminal resistor unit (JEPMC-W6022) between DATA and
/DATA if the unit comes to the end of the network. [Refer to 2.3 [8]
Wiring Layout for Fieldbus.]
7) EtherCAT Type
Connector Name EtherCAT Connector
Cable Side
8P8C Modular Plug
Controller Side
8P8C Modular Jack
Pin No. Signal Name
Description
Applicable cable
diameter
1
TD+
Data s
2
TD-
Data sending -
3
RD+
Data rec
4
–
Disconnected
5
–
Disconnected
6
RD-
Data receiving -
7
–
Disconnected
Front view of
connector on
controller side
8
–
Disconnected
For EtherNet cable, use
a straight STP cable
that possesses the
performance of
Category 5e or more.
B1
A1
A4
B4
8
1
8
1