Alarm group C: Controller abnormality alarm
Controller abnormality occurred.
No.
Cause
Countermeasure
1
The controller is affected by the noise of a peripheral
device and cannot operate normally.
Shut down the power supply of the peripheral device
and operate only
with the ELECYLINDER, then
check to see whether this alarm persists.
If it does not, there is a possibility that the
ELECYLINDER
is affected by the noise from the
peripheral device.
Reconsider the noise countermeasures (grounding,
power line wiring, electrostatic shielding, etc.) for the
peripheral device.
2
If this alarm recurs after performing the inspection
above and improving the power supply environment,
it is highly likely that the controller has failed.
Replace the controller cover assembly.
→For details, refer to "
Controller replacement
(page 8-15 to 16)".