7.3 Troubleshooting with no alarm generated
7-6
7.
Troubleshooting
7.3 Troubleshooting with no alarm generated
Operation failure
[Condition 1] SV/ALM LEDs do not light up
No.
Possible cause
Confirmation/countermeasure
1
The specified power is not supplied.
● Make sure that normal voltage is secured
and wiring processing is correct.
● Also, be sure to check for disconnection or
partial disconnection in connectors and
wiring.
→For details, refer to "3.4/3.5 Wiring
connections".
2
The unit is switched to servo OFF
with the teaching tool.
Turn ON the servo with PC software or teaching
pendant.
3
Controller breakdown
● Replace the controller cover assembly.
→For details, refer to "
Controller
replacement
(page 8-15 to 16)".
● If the unit still does not recover, contact IAI.
[Condition 2] SV/ALM LEDs light up red
No.
Possible cause
Confirmation/countermeasure
1
Alarm generated.
● Connect the teaching tool.
● Upon checking the alarm code, resolve the
cause.
→For details, refer to "7.4 Troubleshooting by
alarm groups".
2
The stop switch of the teaching pendant is
being pressed.
Release the stop switch.
Summary of Contents for EYECYLINDER EC-B6 Series
Page 2: ......
Page 10: ......
Page 28: ...Intro 18 ...
Page 30: ......
Page 50: ...1 20 1 Specifications ...
Page 52: ......
Page 64: ......
Page 84: ......
Page 102: ......
Page 108: ...5 6 5 Preventive Predictive Maintenance ...
Page 110: ......
Page 124: ...6 14 6 Parameters ...
Page 126: ......
Page 144: ...7 18 7 Troubleshooting ...
Page 146: ......
Page 184: ......
Page 188: ......
Page 192: ...10 4 10 Life ...
Page 194: ......
Page 197: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 198: ......
Page 203: ......