185
MAC-based VLAN Parameters:
Items
Description
MAC Address
Indicates the MAC address.
VLAN ID
Indicates the VLAN ID.
Port Memebers
Port members of the MAC-based VLAN entry.
Butons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3
seconds.
Refresh: Click to manually refresh the page.
Protocol-based VLAN Protocol to Group
This page displays the protocols to Group Name (unique for each Group) mapping entries for the switch.
To display the Protocol-Based VLAN configuration in the web interface:
Click Monitor / VCL / Protocol to Group
Check the Auto-Refresh check box to have the page automatically refresh every 3 seconds.
Protocol to Group Mapping Table Parameters:
Items
Description
Frame Type
Frame Type can have one of three values: Ethernet, LLC, or SNAP. On changing the Frame type
field, valid values of the following text field will vary depending on the new frame type selected.
Value
Valid value that can be entered in this text field depends on the option selected from the
preceding Frame Type selection menu. Below are the criteria for 3 different Frame Types.
For Ethernet: Values in the text field when Ethernet is selected as a Frame Type is called etype.
Valid values for etype range from 0x0600-0xffff.
For LLC: Valid value in this case is comprised of two different sub-values:
DSAP: 1-byte long string (0x00-0xff)
SSAP: 1-byte long string (0x00-0xff)
For SNAP: Valid value in this case also is comprised of two different sub-values:
OUI: OUI (Organizationally Unique Identifier) is value in format of xx-xx-xx where each pair (xx)
in string is a hexadecimal value ranges from 0x00-0xff.
PID: If the OUI is hexadecimal 000000, the protocol ID is the Ethernet type (EtherType) field
value for the protocol running on top of SNAP; if the OUI is an OUI for a particular
organization, the protocol ID is a value assigned by that organization to the protocol running on
top of SNAP.
If value of OUI field is 00-00-00 then value of PID will be etype (0x0600-0xffff) and if value of
OUI is other than 00-00-00 then valid value of PID will be any value from 0x0000 to 0xffff.
Group Name
A valid Group Name is a unique 16-character long string for every entry which consists of a
combination of alphabets (a-z or A-Z) and integers (0-9).
Special characters and underscores are not allowed.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3
seconds.
Refresh: Click to manually refresh the page.
Summary of Contents for S81
Page 113: ...112 NOTE Click the Port index to set the QoS Egress Port Schedulers...
Page 117: ...116...