Flow Samper Max
Header
The maximum number of bytes that should be copied from a sampled packet to the sFlow
datagram. Valid range is 14 to 200 bytes with default being 128 bytes. If the maximum datagram
size does not take into account the maximum header size, samples may be dropped.
Counter Poller Enabled Enabled specifies the interval in second between counter poller samples.
STMP Configuration
This function is used to set an Alarm trap. When the switch receives an alarm it will use the STMP server to send an Alarm
email to the designated email address.
To configure the SMTP Alarm configuration in the web interface:
Click Configuration / SMTP Configuration
Scroll to select the Severity level
Specify the parameters in each blank field
Click Apply and click the Save icon in the upper right corner to save the settings or click Reset to cancel. The
Form will return to the previously saved setting.
STMP Configuration Parameters:
Items
Description
Mail Server
The IP address or hostname of the mail server. IP adress is expressed in dotted decimal
notation. This will be the device that sends out the mail for you.
User Name
Specify the username on the mail server.
Password
Specify the password on the mail server.
Sender
Specify the sender name of the alarm email.
Return-Path
Specify the sender email address of the alarm mail. This address will be the “from” address
on the email message.
Email Address 1-6
Email address that would like to receive the alarm message.