B.3.3 SERVICE
CONDITIONS
The machine is designed to operate under the following conditions:
Service conditions
DESCRIPTION RANGE
Environmental temperature
-20°C
45°C
Hydraulic oil temperature
-10°C
80°C
Max working heel
5°
Bearing capacity of the ground supporting the stabilizer legs
> max stabilizer pressure
on the ground
Min distance D between crane and electric power lines
7 m
Max wind speed
50 km/h
Beaufort force: 6 (see E.6)
Weather
Do NOT use during storms
Forbidden work environments
Marine environments
Explosive environments
IP protection class
IP 65
If any of these conditions is not fulfilled, stop work immediately.