Run Mode
3-4
SlideSmart Installation and Reference Manual
Revision C
5
81
0
2'(
Gate status displays appear when the operator is ready and waiting for a gate operation command. When the
menu display is flashing “GATE OPENING” or “GATE CLOSING” a command has been received which
starts the motor and drives the gate. The command may come from a variety of sources: a card reader, push-
button remote, or recognition of a vehicle passing over a free exit loop detector. In all cases, the operator “runs”
the motor when it receives a gate operation command.
8QGHUVWDQGLQJ*DWH6WDWXV'LVSOD\V
The three gate status displays in Figure 3-4 indicate the position or status of the non-moving gate. When
accessing the User or Installer Menus, you must begin at one of these gate status displays.
127(
While accessing the User or Installer Menus, the motor cannot engage and the gate will not
move.
HYSECURITY
GATE OPEN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE STOPPED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
)LJXUH*DWH6WDWXV'LVSOD\V